1993PubMedRequires access

Transcutaneous bilirubinometry: clinical application.

Akmal Laeeq, Muhammad Yasin, Abdul Rashid Chaudhry

Open publisher page 13 citations

Abstract

Simultaneous estimations of serum and transcutaneous bilirubin were done in 105 healthy, full term, jaundiced newborns. A good correlation was found between the transcutaneous and serum bilirubin values with coefficient of correlation 0.774. The observed sensitivity was 90%, specificity 78% and positive predictive value 64% at mean serum bilirubin concentration of 9.92 mg/dl. Two action levels at transcutaneous bilirubin values 15 and 18 were also generated that correlated with low and high serum bilirubin values; they can therefore be used for screening of jaundiced full term babies. This study indicates that the transcutaneous bilirubin meter is useful for screening of jaundiced neonates.

About this research paper

What this paper is about

Simultaneous estimations of serum and transcutaneous bilirubin were done in 105 healthy, full term, jaundiced newborns. A good correlation was found between the transcutaneous and serum bilirubin values with coefficient of correlation 0.774. The observed sensitivity was 90%, specificity 78% and positive predictive value 64% at mean serum bilirubin concentration of 9.92 mg/dl. Two action levels at transcutaneous bilirubin values 15 and 18 were also generated that correlated with low and high serum bilirubin values; they can therefore be used for screening of jaundiced full term babies. This study indicates that the transcutaneous bilirubin meter is useful for screening of jaundiced neonates.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Simultaneous estimations of serum and transcutaneous bilirubin were done in 105 healthy, full term, jaundiced newborns. A good correlation was found between the transcutaneous and serum bilirubin values with coefficient of correlation 0.774. The observed sensitivity was 90%, specificity 78% and positive predictive value 64% at mean serum bilirubin concentration of 9.92 mg/dl. Two action levels at transcutaneous bilirubin values 15 and 18 were also generated that correlated with low and high serum bilirubin values; they can therefore be used for screening of jaundiced full term babies. This study indicates that the transcutaneous bilirubin meter is useful for screening of jaundiced neonates.

Key concepts: Medicine, Bilirubin, Serum bilirubin, Jaundice, Predictive value, Gastroenterology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Transcutaneous bilirubinometry: clinical application. — Research Paper | ScholarLens