[Preparation and evaluation of a time-resolved fluoroimmunoassay kit for CA50 determination].
Jianfeng Hang, Ying-song Wu, Weiwen Xu, Wei-Hong Yu, Ying Huang, Ming Li
Abstract
Jianfeng Hang, Ying-song Wu, Weiwen Xu, Wei-Hong Yu, Ying Huang, Ming Li
Abstract
OBJECTIVE: To prepare a rapid and sensitive diagnostic kit for detection of CA50 based on time-resolved fluoroimmunoassay. METHODS: A sandwich-TRFIA diagmostic kit was developed using anti-CA50 monoclonal antibody and all parameters of the kit were evaluated. RESULTS: The linear measurement range of the kit was (5 - 300) U/ml. The sensitivity was 0.2 U/ml. The intra- and inter-assay coefficients of variation were 4.3% - 8.2% and 7.7% - 11.2%, respectively. There was no cross-reaction with CEA, CA12-5, CA15-3 and AFP. The cross reactivity with CA19-9 was 0.7 U/ml. The correlation coefficient of detection results of 107 blood samples between this newly developed kit and commercially available CA50 RIA kit was 0.901. CONCLUSION: This newly developed CA50-TRFIA kit is a valuable test tool for clinical application with even better sensitivity, specificity and accuracy.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To prepare a rapid and sensitive diagnostic kit for detection of CA50 based on time-resolved fluoroimmunoassay. METHODS: A sandwich-TRFIA diagmostic kit was developed using anti-CA50 monoclonal antibody and all parameters of the kit were evaluated. RESULTS: The linear measurement range of the kit was (5 - 300) U/ml. The sensitivity was 0.2 U/ml. The intra- and inter-assay coefficients of variation were 4.3% - 8.2% and 7.7% - 11.2%, respectively. There was no cross-reaction with CEA, CA12-5, CA15-3 and AFP. The cross reactivity with CA19-9 was 0.7 U/ml. The correlation coefficient of detection results of 107 blood samples between this newly developed kit and commercially available CA50 RIA kit was 0.901. CONCLUSION: This newly developed CA50-TRFIA kit is a valuable test tool for clinical application with even better sensitivity, specificity and accuracy.
Key concepts: Coefficient of variation, Chromatography, Monoclonal antibody, Correlation coefficient, Chemistry, Medicine, Antibody, Immunology