1986•Analytical LettersRequires access

High Performance Liquid Chromatographic Assay of Phenacemide in Tablets

H.W. Jun, Nagwa H. Foda, S. C.

Open publisher page 1 citations

Abstract

A rapid, specific and reliable high-performance liquid chromatographic assay of phenacemide in tablets has been developed. Reversed-phase chromatography was conducted using a mobile phase of acetonitrile and acetate buffer, pH 4.2 (50% V/V) and detection at 254 nm. The recovery and coefficient of variation from six placebo samples of 100 mg were 100.2% and 0.57%, respectively. The percent recovery of 10 replicate commercial tablets was 101.1% of the label amount and its coefficient of variation was 0.95%. Regression analyses of three standard plots in the concentration range of 15-150 μ g/ml obtained on three different days gave a correlation coefficient > 0.999 and the coefficient of variation for their slopes <2%. The HPLC method is rapid as it takes - 1 hour to analyze six commercial tablets compared with 6 hours consumed by the USP method. The assay was precise within day and between days as indicated by ANOVA test.

About this research paper

What this paper is about

A rapid, specific and reliable high-performance liquid chromatographic assay of phenacemide in tablets has been developed. Reversed-phase chromatography was conducted using a mobile phase of acetonitrile and acetate buffer, pH 4.2 (50% V/V) and detection at 254 nm. The recovery and coefficient of variation from six placebo samples of 100 mg were 100.2% and 0.57%, respectively. The percent recovery of 10 replicate commercial tablets was 101.1% of the label amount and its coefficient of variation was 0.95%. Regression analyses of three standard plots in the concentration range of 15-150 μ g/ml obtained on three different days gave a correlation coefficient > 0.999 and the coefficient of variation for their slopes <2%. The HPLC method is rapid as it takes - 1 hour to analyze six commercial tablets compared with 6 hours consumed by the USP method. The assay was precise within day and between days as indicated by ANOVA test.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid, specific and reliable high-performance liquid chromatographic assay of phenacemide in tablets has been developed. Reversed-phase chromatography was conducted using a mobile phase of acetonitrile and acetate buffer, pH 4.2 (50% V/V) and detection at 254 nm. The recovery and coefficient of variation from six placebo samples of 100 mg were 100.2% and 0.57%, respectively. The percent recovery of 10 replicate commercial tablets was 101.1% of the label amount and its coefficient of variation was 0.95%. Regression analyses of three standard plots in the concentration range of 15-150 μ g/ml obtained on three different days gave a correlation coefficient > 0.999 and the coefficient of variation for their slopes <2%. The HPLC method is rapid as it takes - 1 hour to analyze six commercial tablets compared with 6 hours consumed by the USP method. The assay was precise within day and between days as indicated by ANOVA test.

Key concepts: Chemistry, Chromatography, Coefficient of variation, High-performance liquid chromatography, Correlation coefficient, Replicate, Phosphate buffered saline, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
High Performance Liquid Chromatographic Assay of Phenacemide in Tablets — Research Paper | ScholarLens