1989•Clinical Chemistry and Laboratory Medicine (CCLM)Open access

A Candidate Reference Method for the Determination of Uric Acid in Serum Based on High Performance Liquid Chromatography, Compared with an Isotope Dilution-Gas Chromatography-Mass Spectrometer Method

Rüdiger Kock, Bert Delvoux, U. Tillmanns, H. Greiling

Open full text 7 citations

Abstract

A method based on isocratic high performance liquid chromatography (HPLC) with UV detection at 292 nm is proposed as a candidate reference method for the determination of uric acid. Data obtained by this method are compared with those from an isotope dilution-gas chromatography-mass spectrometric method (ID-GC-MS), using [1,3-15N2]uric acid as internal standard and selected mass detection at m/z = 456 and m/z = 458. The inaccuracy of the ID-GC-MS method is maximally 0.4% for NBS-SRM-909 control sera with a concentration of 483 mumol/l. The coefficient of variation between days is 0.26%-0.80% and 0.37-0.90% for 14 control sera from other suppliers. The maximum bias of the HPLC method is 0.6%, and the coefficient of variation between days is 0.31%-0.65% for NBS-SRM-909 control sera. The coefficient of variation between days for the other 14 control sera tested is 0.35%-0.66%. Comparison of the HPLC method with the reference ID-GC-MS method resulted in a coefficient of correlation of r = 0.9998 (n = 14). The concentration of uric acid in the tested control sera ranged from 160 to 624 mumol/l.

Open-access reader

About this research paper

What this paper is about

A method based on isocratic high performance liquid chromatography (HPLC) with UV detection at 292 nm is proposed as a candidate reference method for the determination of uric acid. Data obtained by this method are compared with those from an isotope dilution-gas chromatography-mass spectrometric method (ID-GC-MS), using [1,3-15N2]uric acid as internal standard and selected mass detection at m/z = 456 and m/z = 458. The inaccuracy of the ID-GC-MS method is maximally 0.4% for NBS-SRM-909 control sera with a concentration of 483 mumol/l. The coefficient of variation between days is 0.26%-0.80% and 0.37-0.90% for 14 control sera from other suppliers. The maximum bias of the HPLC method is 0.6%, and the coefficient of variation between days is 0.31%-0.65% for NBS-SRM-909 control sera. The coefficient of variation between days for the other 14 control sera tested is 0.35%-0.66%. Comparison of the HPLC method with the reference ID-GC-MS method resulted in a coefficient of correlation of r = 0.9998 (n = 14). The concentration of uric acid in the tested control sera ranged from 160 to 624 mumol/l.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method based on isocratic high performance liquid chromatography (HPLC) with UV detection at 292 nm is proposed as a candidate reference method for the determination of uric acid. Data obtained by this method are compared with those from an isotope dilution-gas chromatography-mass spectrometric method (ID-GC-MS), using [1,3-15N2]uric acid as internal standard and selected mass detection at m/z = 456 and m/z = 458. The inaccuracy of the ID-GC-MS method is maximally 0.4% for NBS-SRM-909 control sera with a concentration of 483 mumol/l. The coefficient of variation between days is 0.26%-0.80% and 0.37-0.90% for 14 control sera from other suppliers. The maximum bias of the HPLC method is 0.6%, and the coefficient of variation between days is 0.31%-0.65% for NBS-SRM-909 control sera. The coefficient of variation between days for the other 14 control sera tested is 0.35%-0.66%. Comparison of the HPLC method with the reference ID-GC-MS method resulted in a coefficient of correlation of r = 0.9998 (n = 14). The concentration of uric acid in the tested control sera ranged from 160 to 624 mumol/l.

Key concepts: Chromatography, Coefficient of variation, Chemistry, Isotope dilution, High-performance liquid chromatography, Mass spectrometry, Correlation coefficient, Gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
A Candidate Reference Method for the Determination of Uric Acid in Serum Based on High Performance Liquid Chromatography, Compared with an Isotope Dilution-Gas Chromatography-Mass Spectrometer Method — Research Paper | ScholarLens