Solid Phase Extraction and High Performance Liquid Chromatographic Determination of Sorbic Acid and Benzoic Acid in Meat Products
Zheng Si-hui
Abstract
Zheng Si-hui
Abstract
The purpose of this study was to develop a solid phase extraction and high performance liquid chromatographic method for the determination of benzoic acid and sobic acid in meat products. The procedure was based on extraction of test portions with hot water in an ultrasonic filed, 5 min high-speed centrifugation, dilution to 25 ml, clean-up using a C18 SPE cartridge to remove macromolecular substances like protein, and filtration through 0.45 μm membrane followed by HPLC analysis of the extracts. In the range of 20-100 mg/L, concentrations of benzoic acid and sorbic acid both displayed a good linear relationship with HPLC peak area (r0.9986), and the precision RSDs of the method for determining them were 3.02% and 3.05%, respectively. The recoveries at three spiked levels were between 101.79% and 105.28%. The method is simple, rapid and easy to operate, and has high sensitivity and wide linear range.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The purpose of this study was to develop a solid phase extraction and high performance liquid chromatographic method for the determination of benzoic acid and sobic acid in meat products. The procedure was based on extraction of test portions with hot water in an ultrasonic filed, 5 min high-speed centrifugation, dilution to 25 ml, clean-up using a C18 SPE cartridge to remove macromolecular substances like protein, and filtration through 0.45 μm membrane followed by HPLC analysis of the extracts. In the range of 20-100 mg/L, concentrations of benzoic acid and sorbic acid both displayed a good linear relationship with HPLC peak area (r0.9986), and the precision RSDs of the method for determining them were 3.02% and 3.05%, respectively. The recoveries at three spiked levels were between 101.79% and 105.28%. The method is simple, rapid and easy to operate, and has high sensitivity and wide linear range.
Key concepts: Sorbic acid, Chromatography, Chemistry, Benzoic acid, Extraction (chemistry), High-performance liquid chromatography, Solid phase extraction, Centrifugation