2014Journal of Anyang Normal UniversityRequires access

Determination of Copper and Iron in Import Grape wine by ICP-AES with Microwave Digestion

Xing Rong-hu

Open publisher page 0 citations

Abstract

The copper and iron in import grape wine were detected by ICP-AES with microwave digestion. Compared with traditional method-AAS,this method has many advantages,for example: wide linear range,low detection limit,high sensitivity, rapid,simple and convenient. The experiment results indicated that optional experimental conditions are as follow: the amount of sample was 2. 5 mL,the amount of digestion liquid was 6 mL,the best temperature was 185℃. Good linear relationship of Fe was observed in the range of 0-0. 8 μg·mL-1with correlation coefficient was 0. 9992. Good linear relationship of Cu was observed in the range of 0 ~ 1. 2 μg·mL-1with correlation coefficient was 0. 9998. The average recovery of Fe and Cu was 93. 33% ~ 97. 33% and 92. 00% ~ 96. 40% with RSD of 0. 73% ~ 0. 82% and 1. 66% ~ 1. 74%.

About this research paper

What this paper is about

The copper and iron in import grape wine were detected by ICP-AES with microwave digestion. Compared with traditional method-AAS,this method has many advantages,for example: wide linear range,low detection limit,high sensitivity, rapid,simple and convenient. The experiment results indicated that optional experimental conditions are as follow: the amount of sample was 2. 5 mL,the amount of digestion liquid was 6 mL,the best temperature was 185℃. Good linear relationship of Fe was observed in the range of 0-0. 8 μg·mL-1with correlation coefficient was 0. 9992. Good linear relationship of Cu was observed in the range of 0 ~ 1. 2 μg·mL-1with correlation coefficient was 0. 9998. The average recovery of Fe and Cu was 93. 33% ~ 97. 33% and 92. 00% ~ 96. 40% with RSD of 0. 73% ~ 0. 82% and 1. 66% ~ 1. 74%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The copper and iron in import grape wine were detected by ICP-AES with microwave digestion. Compared with traditional method-AAS,this method has many advantages,for example: wide linear range,low detection limit,high sensitivity, rapid,simple and convenient. The experiment results indicated that optional experimental conditions are as follow: the amount of sample was 2. 5 mL,the amount of digestion liquid was 6 mL,the best temperature was 185℃. Good linear relationship of Fe was observed in the range of 0-0. 8 μg·mL-1with correlation coefficient was 0. 9992. Good linear relationship of Cu was observed in the range of 0 ~ 1. 2 μg·mL-1with correlation coefficient was 0. 9998. The average recovery of Fe and Cu was 93. 33% ~ 97. 33% and 92. 00% ~ 96. 40% with RSD of 0. 73% ~ 0. 82% and 1. 66% ~ 1. 74%.

Key concepts: Wine, Microwave digestion, Linear correlation, Copper, Correlation coefficient, Linear relationship, Detection limit, Inductively coupled plasma atomic emission spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Copper and Iron in Import Grape wine by ICP-AES with Microwave Digestion — Research Paper | ScholarLens