2010•Pharmaceutical biotechnologyRequires access

HPLC Determination of Ginsenoside Rg1 in Gucining Tablets

Yao Long-feng

Open publisher page 0 citations

Abstract

To establish a HPLC method for the content determination of Ginsenoside Rg1 in Gucining tablets,the HPLC was performed on a Merck C18(250mm×4.6mm)chromatography column gradient eluted with acetonitrile-water at the flow rate of 1.0mL /min.The detection wavelength was set at 203nm.Results showed that the linear response range was:0.201~0.603μg/mL,r=0.9994.The mean recoveries was 100.3%(n=9),and RSD=1.34%.This method is simple,quick and accurate.Therefore it is suitable for the quality control of content determination of Ginsenoside Rg1 in Gucining tablets.

About this research paper

What this paper is about

To establish a HPLC method for the content determination of Ginsenoside Rg1 in Gucining tablets,the HPLC was performed on a Merck C18(250mm×4.6mm)chromatography column gradient eluted with acetonitrile-water at the flow rate of 1.0mL /min.The detection wavelength was set at 203nm.Results showed that the linear response range was:0.201~0.603μg/mL,r=0.9994.The mean recoveries was 100.3%(n=9),and RSD=1.34%.This method is simple,quick and accurate.Therefore it is suitable for the quality control of content determination of Ginsenoside Rg1 in Gucining tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish a HPLC method for the content determination of Ginsenoside Rg1 in Gucining tablets,the HPLC was performed on a Merck C18(250mm×4.6mm)chromatography column gradient eluted with acetonitrile-water at the flow rate of 1.0mL /min.The detection wavelength was set at 203nm.Results showed that the linear response range was:0.201~0.603μg/mL,r=0.9994.The mean recoveries was 100.3%(n=9),and RSD=1.34%.This method is simple,quick and accurate.Therefore it is suitable for the quality control of content determination of Ginsenoside Rg1 in Gucining tablets.

Key concepts: Ginsenoside Rg1, Chromatography, Gradient elution, High-performance liquid chromatography, Chemistry, Content determination, Linear range, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC Determination of Ginsenoside Rg1 in Gucining Tablets — Research Paper | ScholarLens