2009•Journal of Jingmen Technical CollegeRequires access

Determination of Ginsenoside Rg_1 and Notoginsecoside R_1 in Guyuling Tablets by HPLC

Mian Zhang

Open publisher page 0 citations

Abstract

Objective:To establish the determination method of Ginsenoside Rg1 and Notoginsecoside R1 in Guyuling Tablets.Methods: HPLC with C-18 column was used,and the mobile phase was acetonitrile-water(18∶82).The flow rate was 1.0 mL·min-1.The detection wavelength was at 203 nm.Results:The standard curve equation of Ginsenoside Rg1 was Y=2.829X+4.167(r=0.999 9,n=5),the linear range was 3.0~22.5 μg.The standard curve equation of Notoginsecoside R1 was Y=7.580X-3.971(r=0.999 6,n=5),the linear range was 1.0~7.5 μg.The recovery were 98.95% and 99.27% respectively.Conclusion:This method is accurate and sensitive,it can be used for the quality control of Guyuling Tablets.

About this research paper

What this paper is about

Objective:To establish the determination method of Ginsenoside Rg1 and Notoginsecoside R1 in Guyuling Tablets.Methods: HPLC with C-18 column was used,and the mobile phase was acetonitrile-water(18∶82).The flow rate was 1.0 mL·min-1.The detection wavelength was at 203 nm.Results:The standard curve equation of Ginsenoside Rg1 was Y=2.829X+4.167(r=0.999 9,n=5),the linear range was 3.0~22.5 μg.The standard curve equation of Notoginsecoside R1 was Y=7.580X-3.971(r=0.999 6,n=5),the linear range was 1.0~7.5 μg.The recovery were 98.95% and 99.27% respectively.Conclusion:This method is accurate and sensitive,it can be used for the quality control of Guyuling Tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish the determination method of Ginsenoside Rg1 and Notoginsecoside R1 in Guyuling Tablets.Methods: HPLC with C-18 column was used,and the mobile phase was acetonitrile-water(18∶82).The flow rate was 1.0 mL·min-1.The detection wavelength was at 203 nm.Results:The standard curve equation of Ginsenoside Rg1 was Y=2.829X+4.167(r=0.999 9,n=5),the linear range was 3.0~22.5 μg.The standard curve equation of Notoginsecoside R1 was Y=7.580X-3.971(r=0.999 6,n=5),the linear range was 1.0~7.5 μg.The recovery were 98.95% and 99.27% respectively.Conclusion:This method is accurate and sensitive,it can be used for the quality control of Guyuling Tablets.

Key concepts: Chromatography, High-performance liquid chromatography, Ginsenoside Rg1, Ginsenoside, Linear range, Chemistry, Standard curve, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ginsenoside Rg_1 and Notoginsecoside R_1 in Guyuling Tablets by HPLC — Research Paper | ScholarLens