Extraction and Examination of Chlorogenic Acid from Flos Lonicerae
Zesheng Zhang
Abstract
Zesheng Zhang
Abstract
Optimization of the extracting method of chlorogenic acid from Flos Lonicerae was studied by several different methods. Two different ways of Ultraviolet (UV) and Visible Spectrophotometr and High Performance Liquid Chromatography (HPLC) have been carried out for the quantitative and qualitative determination of chlorogenic acid in Flos Lonicerae. Inhibition test against pathogenic bacteria has been done with Flos Lonicerae ethanol and chlorogenic acid. The results of chlorogenic acid extraction showed that chlorogenic acid tiptop absorb-apex was 324nm, with ethanol of 70% concentration extraction was remarkably superior to other methods. The content of chlorogenic acid with 70% ethanol extraction was 43.35%, so the ethanol with 70% concentration extraction was the optimum condition. The antibacterial action of chlorogenic acid on Escherichia in vitro Coliand extracted with 70% ethanol from Flos Lonicerae showed that Flos Lonicerae had strong antimicrobial activity.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Optimization of the extracting method of chlorogenic acid from Flos Lonicerae was studied by several different methods. Two different ways of Ultraviolet (UV) and Visible Spectrophotometr and High Performance Liquid Chromatography (HPLC) have been carried out for the quantitative and qualitative determination of chlorogenic acid in Flos Lonicerae. Inhibition test against pathogenic bacteria has been done with Flos Lonicerae ethanol and chlorogenic acid. The results of chlorogenic acid extraction showed that chlorogenic acid tiptop absorb-apex was 324nm, with ethanol of 70% concentration extraction was remarkably superior to other methods. The content of chlorogenic acid with 70% ethanol extraction was 43.35%, so the ethanol with 70% concentration extraction was the optimum condition. The antibacterial action of chlorogenic acid on Escherichia in vitro Coliand extracted with 70% ethanol from Flos Lonicerae showed that Flos Lonicerae had strong antimicrobial activity.
Key concepts: Chlorogenic acid, Flos, Chemistry, Chromatography, Extraction (chemistry), Ethanol, High-performance liquid chromatography, Biochemistry