2013•Petrochemical Industry ApplicationRequires access

Study of determination of cyanide in water and wastewater by flow injection spectrophotometry

Huo Zongquan

Open publisher page 0 citations

Abstract

A simple and rapid method of determination the concentration of cyanide in water and wastewater was studied by flow injection spectrophotometric method (GB/T8538-2008). The results show that the method had a good correlation coefficient (0.999 9),the method detection limit was 0.000 28 mg/L(CN - ),the RSD was 3.2 %(0.01mg/L)and 1.3 %(0.09mg/L), the average recovery rate of low concentration(0.01 mg/L)and high concentration(0.09 mg/L) which included groundwater, surface water and wastewater were 97.0 %,95.9 %,84.4 % and 103.9 %,102.1 %,96.2 %,respectively.

About this research paper

What this paper is about

A simple and rapid method of determination the concentration of cyanide in water and wastewater was studied by flow injection spectrophotometric method (GB/T8538-2008). The results show that the method had a good correlation coefficient (0.999 9),the method detection limit was 0.000 28 mg/L(CN - ),the RSD was 3.2 %(0.01mg/L)and 1.3 %(0.09mg/L), the average recovery rate of low concentration(0.01 mg/L)and high concentration(0.09 mg/L) which included groundwater, surface water and wastewater were 97.0 %,95.9 %,84.4 % and 103.9 %,102.1 %,96.2 %,respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple and rapid method of determination the concentration of cyanide in water and wastewater was studied by flow injection spectrophotometric method (GB/T8538-2008). The results show that the method had a good correlation coefficient (0.999 9),the method detection limit was 0.000 28 mg/L(CN - ),the RSD was 3.2 %(0.01mg/L)and 1.3 %(0.09mg/L), the average recovery rate of low concentration(0.01 mg/L)and high concentration(0.09 mg/L) which included groundwater, surface water and wastewater were 97.0 %,95.9 %,84.4 % and 103.9 %,102.1 %,96.2 %,respectively.

Key concepts: Wastewater, Chemistry, Cyanide, Correlation coefficient, Spectrophotometry, Detection limit, Chromatography, Groundwater

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of determination of cyanide in water and wastewater by flow injection spectrophotometry — Research Paper | ScholarLens