2014•Huanjing jiance guanli yu jishuRequires access

Determination of Total Nitrogen in Water and Wastewater by Continuous Flow Analysis and Spectrophotometric Method

Qin Lv

Open publisher page 1 citations

Abstract

Applicability of continuous flow analysis and spectrophotometric method to measure total nitrogen in water and waste water was studied. Calibration results of 6 laboratories showed good linear regression in concentration range between 0 mg / L and 10. 0 mg / L with correlation coefficient varied from 0. 999 6 to 0. 999 9. The method detection limit was 0. 04 mg / L and the quantitation limit was 0. 16 mg / L. The test results of certified reference material was in the permission range,RSD ranged from 0. 4% to 9. 6%. The recovery rate of real water samples was between 92. 0% ~ 111% 。Therefore the aforesaid method shows no significant difference compared with national standard method. The interference factor and elimination method was discussed.

About this research paper

What this paper is about

Applicability of continuous flow analysis and spectrophotometric method to measure total nitrogen in water and waste water was studied. Calibration results of 6 laboratories showed good linear regression in concentration range between 0 mg / L and 10. 0 mg / L with correlation coefficient varied from 0. 999 6 to 0. 999 9. The method detection limit was 0. 04 mg / L and the quantitation limit was 0. 16 mg / L. The test results of certified reference material was in the permission range,RSD ranged from 0. 4% to 9. 6%. The recovery rate of real water samples was between 92. 0% ~ 111% 。Therefore the aforesaid method shows no significant difference compared with national standard method. The interference factor and elimination method was discussed.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Applicability of continuous flow analysis and spectrophotometric method to measure total nitrogen in water and waste water was studied. Calibration results of 6 laboratories showed good linear regression in concentration range between 0 mg / L and 10. 0 mg / L with correlation coefficient varied from 0. 999 6 to 0. 999 9. The method detection limit was 0. 04 mg / L and the quantitation limit was 0. 16 mg / L. The test results of certified reference material was in the permission range,RSD ranged from 0. 4% to 9. 6%. The recovery rate of real water samples was between 92. 0% ~ 111% 。Therefore the aforesaid method shows no significant difference compared with national standard method. The interference factor and elimination method was discussed.

Key concepts: Detection limit, Correlation coefficient, Wastewater, Linear regression, Certified reference materials, Chemistry, Calibration curve, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Total Nitrogen in Water and Wastewater by Continuous Flow Analysis and Spectrophotometric Method — Research Paper | ScholarLens