2006•Chinese Journal of Public Health EngineeringRequires access

Determination of Total Cyanide in Water by Flow Injection

Deng Bao-ju

Open publisher page 0 citations

Abstract

Objective To Establish a method of using flow injection in-line cyanide distillation to determine total cyanide in water and wastewater.Methods A QC8000 analyzer in-line cyanide distillation was used.Firstly,a liquid sample was mixed with phosphoric acid and heated to 140℃,then metal-CN~-complexes was irradiated by UV to break down.The HCN(g) from the sample matrix passed through a Teflon membrane and was trapped into a sodium hydroxide solution.The CN~was determined colorimetrically(pyridine-barbituric acid chemistry) at 570 nm.Both standards and samples were distilled in-line.Results The linear range of the method was 2~100 μg/L,detected limit was 0.21 μg/L,The recovery rates were 94.4%~105%.Correlation coefficient was above 0.999.Conclusion The method is simple and sensitive compared with method of standard.

About this research paper

What this paper is about

Objective To Establish a method of using flow injection in-line cyanide distillation to determine total cyanide in water and wastewater.Methods A QC8000 analyzer in-line cyanide distillation was used.Firstly,a liquid sample was mixed with phosphoric acid and heated to 140℃,then metal-CN~-complexes was irradiated by UV to break down.The HCN(g) from the sample matrix passed through a Teflon membrane and was trapped into a sodium hydroxide solution.The CN~was determined colorimetrically(pyridine-barbituric acid chemistry) at 570 nm.Both standards and samples were distilled in-line.Results The linear range of the method was 2~100 μg/L,detected limit was 0.21 μg/L,The recovery rates were 94.4%~105%.Correlation coefficient was above 0.999.Conclusion The method is simple and sensitive compared with method of standard.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To Establish a method of using flow injection in-line cyanide distillation to determine total cyanide in water and wastewater.Methods A QC8000 analyzer in-line cyanide distillation was used.Firstly,a liquid sample was mixed with phosphoric acid and heated to 140℃,then metal-CN~-complexes was irradiated by UV to break down.The HCN(g) from the sample matrix passed through a Teflon membrane and was trapped into a sodium hydroxide solution.The CN~was determined colorimetrically(pyridine-barbituric acid chemistry) at 570 nm.Both standards and samples were distilled in-line.Results The linear range of the method was 2~100 μg/L,detected limit was 0.21 μg/L,The recovery rates were 94.4%~105%.Correlation coefficient was above 0.999.Conclusion The method is simple and sensitive compared with method of standard.

Key concepts: Cyanide, Distilled water, Chemistry, Sodium hydroxide, Phosphoric acid, Distillation, Barbituric acid, Flow injection analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Total Cyanide in Water by Flow Injection — Research Paper | ScholarLens