2007•Journal of Suzhou CollegeRequires access

Studies on the Determination of Paeoniflorin Mensure of Paeonia Suffruticosa Andrl

Daiyin Peng

Open publisher page 0 citations

Abstract

Objective: To establish the method for determination of Paeoniflorin in Paeonia suffruticosa Andrl.Method: HPLC analysis was carried out on VP-ODS column and CH3CN-1.0ml/LH3PO4(19:81) as the mobile phase.The detection wave length was 230nm.Result: The method was linear at the range of 0.096-0.48m g/ml(r = 0.999 7),and the average recovery was 96.36%,RSD was 0.56%(n=5).Conclusion: The method is simple,accurate,highly sensitive and reproducible.It may be used for the quantitative determination of Paeoniflorin in Paeonia suffruticosa Andrl.

About this research paper

What this paper is about

Objective: To establish the method for determination of Paeoniflorin in Paeonia suffruticosa Andrl.Method: HPLC analysis was carried out on VP-ODS column and CH3CN-1.0ml/LH3PO4(19:81) as the mobile phase.The detection wave length was 230nm.Result: The method was linear at the range of 0.096-0.48m g/ml(r = 0.999 7),and the average recovery was 96.36%,RSD was 0.56%(n=5).Conclusion: The method is simple,accurate,highly sensitive and reproducible.It may be used for the quantitative determination of Paeoniflorin in Paeonia suffruticosa Andrl.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish the method for determination of Paeoniflorin in Paeonia suffruticosa Andrl.Method: HPLC analysis was carried out on VP-ODS column and CH3CN-1.0ml/LH3PO4(19:81) as the mobile phase.The detection wave length was 230nm.Result: The method was linear at the range of 0.096-0.48m g/ml(r = 0.999 7),and the average recovery was 96.36%,RSD was 0.56%(n=5).Conclusion: The method is simple,accurate,highly sensitive and reproducible.It may be used for the quantitative determination of Paeoniflorin in Paeonia suffruticosa Andrl.

Key concepts: Paeoniflorin, Paeonia suffruticosa, Chromatography, High-performance liquid chromatography, Paeonia lactiflora, Chemistry, Traditional medicine, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Studies on the Determination of Paeoniflorin Mensure of Paeonia Suffruticosa Andrl — Research Paper | ScholarLens