2013•Laboratory MedicineRequires access

Establishment of TRFIA for anti-thyroglobulin antibody and its clinical application

LI Yueson

Open publisher page 0 citations

Abstract

Objective To establish a time-resolved fluoroimmunoassay(TRFIA)for anti-thyroglobulin antibody(TgAb).Methods The thyroglobulin antigen was coated on the 96 well plates.A goat anti-mouse IgG-europium(Eu3+) was used to the detection.Serum TgAb level was detected by TRFIA.Results The sensitivity was 1.0 IU/mL.The within-run coefficient of variation(CV)was 3.3%-4.1%.The between-run CV was 3.7%-4.7%.The average recovery was 97.9%.The kit was stable.The correlation coefficient with TgAb by electrochemiluminescence immunoassay(ECLIA) was 0.881 3.The TgAb levels between males and females had no statistical significance.The normal range of TgAb was ≤ 110 IU/mL.Conclusions The established TRFIA for the detection of TgAb in serum is a sensitive and reliable assay,which would be useful for the clinical diagnosis of thyroid diseases.

About this research paper

What this paper is about

Objective To establish a time-resolved fluoroimmunoassay(TRFIA)for anti-thyroglobulin antibody(TgAb).Methods The thyroglobulin antigen was coated on the 96 well plates.A goat anti-mouse IgG-europium(Eu3+) was used to the detection.Serum TgAb level was detected by TRFIA.Results The sensitivity was 1.0 IU/mL.The within-run coefficient of variation(CV)was 3.3%-4.1%.The between-run CV was 3.7%-4.7%.The average recovery was 97.9%.The kit was stable.The correlation coefficient with TgAb by electrochemiluminescence immunoassay(ECLIA) was 0.881 3.The TgAb levels between males and females had no statistical significance.The normal range of TgAb was ≤ 110 IU/mL.Conclusions The established TRFIA for the detection of TgAb in serum is a sensitive and reliable assay,which would be useful for the clinical diagnosis of thyroid diseases.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a time-resolved fluoroimmunoassay(TRFIA)for anti-thyroglobulin antibody(TgAb).Methods The thyroglobulin antigen was coated on the 96 well plates.A goat anti-mouse IgG-europium(Eu3+) was used to the detection.Serum TgAb level was detected by TRFIA.Results The sensitivity was 1.0 IU/mL.The within-run coefficient of variation(CV)was 3.3%-4.1%.The between-run CV was 3.7%-4.7%.The average recovery was 97.9%.The kit was stable.The correlation coefficient with TgAb by electrochemiluminescence immunoassay(ECLIA) was 0.881 3.The TgAb levels between males and females had no statistical significance.The normal range of TgAb was ≤ 110 IU/mL.Conclusions The established TRFIA for the detection of TgAb in serum is a sensitive and reliable assay,which would be useful for the clinical diagnosis of thyroid diseases.

Key concepts: Thyroglobulin, Medicine, Antibody, Coefficient of variation, Subclinical infection, Immunoassay, Thyroid, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Establishment of TRFIA for anti-thyroglobulin antibody and its clinical application — Research Paper | ScholarLens