2007•Laboratory MedicineRequires access

Mutual interference between serum thyroglobulin and anti-thyroglbulin antibody in chemiluminescent immunoassay

LU Hanku

Open publisher page 0 citations

Abstract

Objective To investigate the mutual interference between serum thyroglobulin(Tg) and anti-thyroglbulinantibody(TgAb) in chemiluminescent immunoassay(CLIA). Methods Serum Tg and TgAb were measured by automated CLIA.Tg or TgAb recoveries were determined in serum samples blended with sera of different concentrations of TgAb or Tg. Results Tg recovery rate was 93%-112% in low TgAb sera,17%-40% in high TgAb sera with negative correlation with TgAb concentrations (r_s=-0.877,P=0.001),while TgAb recovery rate was 76%-108% in low Tg sera,66%-98% in high Tg sera with negative correlation with Tg concentrations (r_s=-0.881,P=0.004). Conclusions Mutual but not equal interferences between serum Tg and TgAb are present in CLIA,resulting in falsely low concentration in a concentration-dependent manner;TgAb interference existes even at low level and Tg interference existes only at high level.

About this research paper

What this paper is about

Objective To investigate the mutual interference between serum thyroglobulin(Tg) and anti-thyroglbulinantibody(TgAb) in chemiluminescent immunoassay(CLIA). Methods Serum Tg and TgAb were measured by automated CLIA.Tg or TgAb recoveries were determined in serum samples blended with sera of different concentrations of TgAb or Tg. Results Tg recovery rate was 93%-112% in low TgAb sera,17%-40% in high TgAb sera with negative correlation with TgAb concentrations (r_s=-0.877,P=0.001),while TgAb recovery rate was 76%-108% in low Tg sera,66%-98% in high Tg sera with negative correlation with Tg concentrations (r_s=-0.881,P=0.004). Conclusions Mutual but not equal interferences between serum Tg and TgAb are present in CLIA,resulting in falsely low concentration in a concentration-dependent manner;TgAb interference existes even at low level and Tg interference existes only at high level.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the mutual interference between serum thyroglobulin(Tg) and anti-thyroglbulinantibody(TgAb) in chemiluminescent immunoassay(CLIA). Methods Serum Tg and TgAb were measured by automated CLIA.Tg or TgAb recoveries were determined in serum samples blended with sera of different concentrations of TgAb or Tg. Results Tg recovery rate was 93%-112% in low TgAb sera,17%-40% in high TgAb sera with negative correlation with TgAb concentrations (r_s=-0.877,P=0.001),while TgAb recovery rate was 76%-108% in low Tg sera,66%-98% in high Tg sera with negative correlation with Tg concentrations (r_s=-0.881,P=0.004). Conclusions Mutual but not equal interferences between serum Tg and TgAb are present in CLIA,resulting in falsely low concentration in a concentration-dependent manner;TgAb interference existes even at low level and Tg interference existes only at high level.

Key concepts: Immunoassay, Internal medicine, Chemistry, Antibody, Chemiluminescence, Chemiluminescent immunoassay, Serum concentration, Thyroglobulin

Related papers

Back to paper searchBrowse research topicsOriginal source
Mutual interference between serum thyroglobulin and anti-thyroglbulin antibody in chemiluminescent immunoassay — Research Paper | ScholarLens