2008Unpublished venueRequires access

Determining total phosphorus in water with method of flow injection

Xiaoyan Wang, Xiaojing Zhao

Open publisher page 0 citations

Abstract

When we used Lachat QC8500 three-channel flow injection analyzer,we made different forms of phosphorus changed into phosphate by method of ultraviolet digestion with potassium peroxy disulfate.Orthophosphate and ammonium molybdate generated phosphorus molybdenum compound with reaction of antimony potassium tartrate.Phosphorus molybdenum compound was restored by ascorbic acid into blue compounds,which are absorbed at 880nm.The detection limit of the equipment was 0.0012mg/L.The linear range was 0.05~1mg/L(r0.999)and recover rate of standard addition is 95.0%~104%.Compared with method of ammonium molybdate spectrophotography in GB11893-89,the result had not significant difference.Test result shows that the method is simple,fast,accurate and applicable to determine total phosphorus in water.

About this research paper

What this paper is about

When we used Lachat QC8500 three-channel flow injection analyzer,we made different forms of phosphorus changed into phosphate by method of ultraviolet digestion with potassium peroxy disulfate.Orthophosphate and ammonium molybdate generated phosphorus molybdenum compound with reaction of antimony potassium tartrate.Phosphorus molybdenum compound was restored by ascorbic acid into blue compounds,which are absorbed at 880nm.The detection limit of the equipment was 0.0012mg/L.The linear range was 0.05~1mg/L(r0.999)and recover rate of standard addition is 95.0%~104%.Compared with method of ammonium molybdate spectrophotography in GB11893-89,the result had not significant difference.Test result shows that the method is simple,fast,accurate and applicable to determine total phosphorus in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

When we used Lachat QC8500 three-channel flow injection analyzer,we made different forms of phosphorus changed into phosphate by method of ultraviolet digestion with potassium peroxy disulfate.Orthophosphate and ammonium molybdate generated phosphorus molybdenum compound with reaction of antimony potassium tartrate.Phosphorus molybdenum compound was restored by ascorbic acid into blue compounds,which are absorbed at 880nm.The detection limit of the equipment was 0.0012mg/L.The linear range was 0.05~1mg/L(r0.999)and recover rate of standard addition is 95.0%~104%.Compared with method of ammonium molybdate spectrophotography in GB11893-89,the result had not significant difference.Test result shows that the method is simple,fast,accurate and applicable to determine total phosphorus in water.

Key concepts: Ammonium molybdate, Molybdenum blue, Chemistry, Phosphorus, Potassium, Molybdate, Molybdenum, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determining total phosphorus in water with method of flow injection — Research Paper | ScholarLens