2011Physical Testing and Chemical AnalysisRequires access

Determination of Total Phosphorus in Water by FI-Photometry

Chen Zhao

Open publisher page 0 citations

Abstract

A flow-injection analyzer was used for the determination of total phosphorus in water.The water sample was digested with H_2SO_4 and potassium persulfate at 125℃.Phosphosrus,present as ortho phosphate in the sample solution was reacted with ammonium molybdate to form heteropoly acid the absorbance of which after reduced by ascorbic acid was measured photometrically.Linear relationship between values of absorbance and mass concentration of total phosphorus was obtained in the range within 1.0 mg·L~(-1),with values of detection limit (3S/N) of 0.003 mg·L~(-1) and lower limit of determination(10S/N) of 0.012 mg·L~(-1).The proposed method was applied to the determination of total phosphorus in water samples,values of recovery found by standard addition method were in the range of 95.7%-102.5%with RSD's(n = 7) in the range of 1.5%-3.0%.

About this research paper

What this paper is about

A flow-injection analyzer was used for the determination of total phosphorus in water.The water sample was digested with H_2SO_4 and potassium persulfate at 125℃.Phosphosrus,present as ortho phosphate in the sample solution was reacted with ammonium molybdate to form heteropoly acid the absorbance of which after reduced by ascorbic acid was measured photometrically.Linear relationship between values of absorbance and mass concentration of total phosphorus was obtained in the range within 1.0 mg·L~(-1),with values of detection limit (3S/N) of 0.003 mg·L~(-1) and lower limit of determination(10S/N) of 0.012 mg·L~(-1).The proposed method was applied to the determination of total phosphorus in water samples,values of recovery found by standard addition method were in the range of 95.7%-102.5%with RSD's(n = 7) in the range of 1.5%-3.0%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A flow-injection analyzer was used for the determination of total phosphorus in water.The water sample was digested with H_2SO_4 and potassium persulfate at 125℃.Phosphosrus,present as ortho phosphate in the sample solution was reacted with ammonium molybdate to form heteropoly acid the absorbance of which after reduced by ascorbic acid was measured photometrically.Linear relationship between values of absorbance and mass concentration of total phosphorus was obtained in the range within 1.0 mg·L~(-1),with values of detection limit (3S/N) of 0.003 mg·L~(-1) and lower limit of determination(10S/N) of 0.012 mg·L~(-1).The proposed method was applied to the determination of total phosphorus in water samples,values of recovery found by standard addition method were in the range of 95.7%-102.5%with RSD's(n = 7) in the range of 1.5%-3.0%.

Key concepts: Ammonium molybdate, Absorbance, Chemistry, Detection limit, Phosphorus, Ascorbic acid, Potassium, Ammonium

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Total Phosphorus in Water by FI-Photometry — Research Paper | ScholarLens