2007Yufang yixue luntanRequires access

Research on the Determination of Manganese in Urine by Graphite Furnace Atomic Absorption Spectrometry with Digestion at Constant Temperature

Fei Zhao-qua

Open publisher page 0 citations

Abstract

[Objective]To develop a simple and reliable method for the determination of manganese in urine of the population in the community and the workers exposed to manganese.[Methods]Urine samples were digested with digestion apparatus at constant temperature,manganese in urine was tested by Graphite Furnace Atomic Absorption Spectrometry.[Results]The regression equation of the method =0.001+0.028X,r=0.999 7;fine linear relation was at the range of 0.05~20 μg/L.RSD(%) was 3.18%、1.35% and 2.26% in the urine with low,moderate and high concentration of manganese by the examination of degree of accuracy.The recovery was 101.2%、99.2%、100.3% after adding different content of standard solution in 3 urine samples by recovery test.[Conclusion]It is a feasible method to determine manganese in urine,especially for the determination of great quantity of samples.

About this research paper

What this paper is about

[Objective]To develop a simple and reliable method for the determination of manganese in urine of the population in the community and the workers exposed to manganese.[Methods]Urine samples were digested with digestion apparatus at constant temperature,manganese in urine was tested by Graphite Furnace Atomic Absorption Spectrometry.[Results]The regression equation of the method =0.001+0.028X,r=0.999 7;fine linear relation was at the range of 0.05~20 μg/L.RSD(%) was 3.18%、1.35% and 2.26% in the urine with low,moderate and high concentration of manganese by the examination of degree of accuracy.The recovery was 101.2%、99.2%、100.3% after adding different content of standard solution in 3 urine samples by recovery test.[Conclusion]It is a feasible method to determine manganese in urine,especially for the determination of great quantity of samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To develop a simple and reliable method for the determination of manganese in urine of the population in the community and the workers exposed to manganese.[Methods]Urine samples were digested with digestion apparatus at constant temperature,manganese in urine was tested by Graphite Furnace Atomic Absorption Spectrometry.[Results]The regression equation of the method =0.001+0.028X,r=0.999 7;fine linear relation was at the range of 0.05~20 μg/L.RSD(%) was 3.18%、1.35% and 2.26% in the urine with low,moderate and high concentration of manganese by the examination of degree of accuracy.The recovery was 101.2%、99.2%、100.3% after adding different content of standard solution in 3 urine samples by recovery test.[Conclusion]It is a feasible method to determine manganese in urine,especially for the determination of great quantity of samples.

Key concepts: Graphite furnace atomic absorption, Manganese, Urine, Atomic absorption spectroscopy, Chemistry, Graphite, Mass spectrometry, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on the Determination of Manganese in Urine by Graphite Furnace Atomic Absorption Spectrometry with Digestion at Constant Temperature — Research Paper | ScholarLens