2012Anhui nongye kexueRequires access

Comparison of Different Methods for the Detection of Polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI

Shuang Chen

Open publisher page 0 citations

Abstract

[Objective] To compare the content of polydatin in artificial cultivated RHIZOMA ET RADIX POLYGONI CUSPIDATI determined by different methods.[Method] High-performance liquid chromatography(HPLC) and capillary electrophoresis(CE) were adopted to determine the content of polydatin in the artificial cultivars of RHIZOMA ET RADIX POLYGONI CUSPIDATI.Then,the linear range,quantitative reproducibility,detection limit and analysis time of the separation between the two methods were comparatively studied.[Result] High-performance liquid chromatography with fluorescence detection(HPLC-FD) was the optimum method for detecting polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.Following the injection of 10 μl of sample solution,polydatin was separated on a chromatographic column Diamonsil-C18(250 mm×0.46 mm,5 μm) with 25% acetonitrile as mobile phase at the column temperature of 25 ℃,and then quantified by fluorescence detection with the excitation wavelength at 334 nm and the emission wavelength at 408 nm.The flow rate of mobile phase was set to 1.0 ml/min.[Conclusion] HPLC is an ideal method to determine the content of polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.

About this research paper

What this paper is about

[Objective] To compare the content of polydatin in artificial cultivated RHIZOMA ET RADIX POLYGONI CUSPIDATI determined by different methods.[Method] High-performance liquid chromatography(HPLC) and capillary electrophoresis(CE) were adopted to determine the content of polydatin in the artificial cultivars of RHIZOMA ET RADIX POLYGONI CUSPIDATI.Then,the linear range,quantitative reproducibility,detection limit and analysis time of the separation between the two methods were comparatively studied.[Result] High-performance liquid chromatography with fluorescence detection(HPLC-FD) was the optimum method for detecting polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.Following the injection of 10 μl of sample solution,polydatin was separated on a chromatographic column Diamonsil-C18(250 mm×0.46 mm,5 μm) with 25% acetonitrile as mobile phase at the column temperature of 25 ℃,and then quantified by fluorescence detection with the excitation wavelength at 334 nm and the emission wavelength at 408 nm.The flow rate of mobile phase was set to 1.0 ml/min.[Conclusion] HPLC is an ideal method to determine the content of polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] To compare the content of polydatin in artificial cultivated RHIZOMA ET RADIX POLYGONI CUSPIDATI determined by different methods.[Method] High-performance liquid chromatography(HPLC) and capillary electrophoresis(CE) were adopted to determine the content of polydatin in the artificial cultivars of RHIZOMA ET RADIX POLYGONI CUSPIDATI.Then,the linear range,quantitative reproducibility,detection limit and analysis time of the separation between the two methods were comparatively studied.[Result] High-performance liquid chromatography with fluorescence detection(HPLC-FD) was the optimum method for detecting polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.Following the injection of 10 μl of sample solution,polydatin was separated on a chromatographic column Diamonsil-C18(250 mm×0.46 mm,5 μm) with 25% acetonitrile as mobile phase at the column temperature of 25 ℃,and then quantified by fluorescence detection with the excitation wavelength at 334 nm and the emission wavelength at 408 nm.The flow rate of mobile phase was set to 1.0 ml/min.[Conclusion] HPLC is an ideal method to determine the content of polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI.

Key concepts: Chromatography, Radix (gastropod), High-performance liquid chromatography, Chemistry, Detection limit, Linear range, Reproducibility, Excitation wavelength

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Different Methods for the Detection of Polydatin in RHIZOMA ET RADIX POLYGONI CUSPIDATI — Research Paper | ScholarLens