2012China Journal of Chinese Materia MedicaRequires access

Simultaneous determination of contents of five major bioactive components contained in Polygoni Cuspidati Rhizoma et Radix by microwave extraction-ultra performance liquid chromatography

Yan Lu

Open publisher page 2 citations

Abstract

OBJECTIVE: To establish a microwave extraction and UPLC method for simultaneous determination of polydatin, resveratrol, anthraglycoside B, emodin and physicion contained in Polygoni Cuspidati Rhizoma et Radix, in order to provide scientific basis for improving quality standards of Polygoni Cuspidati Rhizoma et Radix. METHOD: The test solutions were prepared in a MDS-8 closed microwave system at 160 degrees C with methanol as the solvent. The UPLC analysis was performed in a Waters Acquity UPLC system. A BEH C18 column (2. 1 mm x 100 mm, 1.7 microm) was adopted for gradient elution with acetonitrile and water as the mobile phase. The temperature of column was 30 degrees C, and the detection wavelength was 226 nm. RESULT: The five active components can be completely extracted in 10 minutes and separated completely in 12 minutes according to UPLC analysis, with a good linearity (r > or = 0. 999 6) within the linear ranges. The average recovery rate was 97.00%-103.7% with RSD < or = 2. 2%. Despite a large difference in content among tested components from Polygoni Cuspidati Rhizoma et Radix, the total content of the five major constituents was relatiely stable (3.683 3%-7.1031%). CONCLUSION: The microwave extraction-ultra performance liquid chromatography method in simultaneous determination for contents of five major bioactive components contained in polygoni cuspidati rhizoma et radix is so rapid and highly reproducible that it can be used for quality control and assessment of Polygoni Cuspidati Rhizoma et Radix.

About this research paper

What this paper is about

OBJECTIVE: To establish a microwave extraction and UPLC method for simultaneous determination of polydatin, resveratrol, anthraglycoside B, emodin and physicion contained in Polygoni Cuspidati Rhizoma et Radix, in order to provide scientific basis for improving quality standards of Polygoni Cuspidati Rhizoma et Radix. METHOD: The test solutions were prepared in a MDS-8 closed microwave system at 160 degrees C with methanol as the solvent. The UPLC analysis was performed in a Waters Acquity UPLC system. A BEH C18 column (2. 1 mm x 100 mm, 1.7 microm) was adopted for gradient elution with acetonitrile and water as the mobile phase. The temperature of column was 30 degrees C, and the detection wavelength was 226 nm. RESULT: The five active components can be completely extracted in 10 minutes and separated completely in 12 minutes according to UPLC analysis, with a good linearity (r > or = 0. 999 6) within the linear ranges. The average recovery rate was 97.00%-103.7% with RSD < or = 2. 2%. Despite a large difference in content among tested components from Polygoni Cuspidati Rhizoma et Radix, the total content of the five major constituents was relatiely stable (3.683 3%-7.1031%). CONCLUSION: The microwave extraction-ultra performance liquid chromatography method in simultaneous determination for contents of five major bioactive components contained in polygoni cuspidati rhizoma et radix is so rapid and highly reproducible that it can be used for quality control and assessment of Polygoni Cuspidati Rhizoma et Radix.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish a microwave extraction and UPLC method for simultaneous determination of polydatin, resveratrol, anthraglycoside B, emodin and physicion contained in Polygoni Cuspidati Rhizoma et Radix, in order to provide scientific basis for improving quality standards of Polygoni Cuspidati Rhizoma et Radix. METHOD: The test solutions were prepared in a MDS-8 closed microwave system at 160 degrees C with methanol as the solvent. The UPLC analysis was performed in a Waters Acquity UPLC system. A BEH C18 column (2. 1 mm x 100 mm, 1.7 microm) was adopted for gradient elution with acetonitrile and water as the mobile phase. The temperature of column was 30 degrees C, and the detection wavelength was 226 nm. RESULT: The five active components can be completely extracted in 10 minutes and separated completely in 12 minutes according to UPLC analysis, with a good linearity (r > or = 0. 999 6) within the linear ranges. The average recovery rate was 97.00%-103.7% with RSD < or = 2. 2%. Despite a large difference in content among tested components from Polygoni Cuspidati Rhizoma et Radix, the total content of the five major constituents was relatiely stable (3.683 3%-7.1031%). CONCLUSION: The microwave extraction-ultra performance liquid chromatography method in simultaneous determination for contents of five major bioactive components contained in polygoni cuspidati rhizoma et radix is so rapid and highly reproducible that it can be used for quality control and assessment of Polygoni Cuspidati Rhizoma et Radix.

Key concepts: Emodin, Chromatography, Radix (gastropod), High-performance liquid chromatography, Chemistry, Extraction (chemistry), Microwave, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of contents of five major bioactive components contained in Polygoni Cuspidati Rhizoma et Radix by microwave extraction-ultra performance liquid chromatography — Research Paper | ScholarLens