2014•Drug Evaluation ResearchRequires access

Simultaneous determination of four constituents in Liuwei Dihuang Capsule by HPLC

XU Can-hu

Open publisher page 0 citations

Abstract

Objective An HPLC method was established for determining four constituents(verbascoside, loganin, paeoniflorin, and paeonolum) in Liuwei Dihuang Capsule. Methods HPLC-gradient elution method was applied. The column was Kromasil C18(250 mm × 4.6 mm, 5 μm). The mobile phase was 1% acetic acid solution(A) and acetonitrile(B). The detection wavelength was set at 245 nm. Results The linear range of density was 6—60 μg/mL for verbascoside, 15—150 μg/mL for loganin, 50—500 μg/mL for paeonolum, and 5—50 μg/mL for paeoniflorin, respectively. The correlation coefficient of all curves were better than 0.999. The average recoveries of four analytes were 98.3% for verbascoside, 99.3% for loganin, 99.0% for paeonolum, and 99.0% for paeoniflorin, and the RSD values were less than 0.9%(n = 9). Conclusion The developed HPLC method could be used for the quality control of Liuwei Dihuang Capsule.

About this research paper

What this paper is about

Objective An HPLC method was established for determining four constituents(verbascoside, loganin, paeoniflorin, and paeonolum) in Liuwei Dihuang Capsule. Methods HPLC-gradient elution method was applied. The column was Kromasil C18(250 mm × 4.6 mm, 5 μm). The mobile phase was 1% acetic acid solution(A) and acetonitrile(B). The detection wavelength was set at 245 nm. Results The linear range of density was 6—60 μg/mL for verbascoside, 15—150 μg/mL for loganin, 50—500 μg/mL for paeonolum, and 5—50 μg/mL for paeoniflorin, respectively. The correlation coefficient of all curves were better than 0.999. The average recoveries of four analytes were 98.3% for verbascoside, 99.3% for loganin, 99.0% for paeonolum, and 99.0% for paeoniflorin, and the RSD values were less than 0.9%(n = 9). Conclusion The developed HPLC method could be used for the quality control of Liuwei Dihuang Capsule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective An HPLC method was established for determining four constituents(verbascoside, loganin, paeoniflorin, and paeonolum) in Liuwei Dihuang Capsule. Methods HPLC-gradient elution method was applied. The column was Kromasil C18(250 mm × 4.6 mm, 5 μm). The mobile phase was 1% acetic acid solution(A) and acetonitrile(B). The detection wavelength was set at 245 nm. Results The linear range of density was 6—60 μg/mL for verbascoside, 15—150 μg/mL for loganin, 50—500 μg/mL for paeonolum, and 5—50 μg/mL for paeoniflorin, respectively. The correlation coefficient of all curves were better than 0.999. The average recoveries of four analytes were 98.3% for verbascoside, 99.3% for loganin, 99.0% for paeonolum, and 99.0% for paeoniflorin, and the RSD values were less than 0.9%(n = 9). Conclusion The developed HPLC method could be used for the quality control of Liuwei Dihuang Capsule.

Key concepts: Loganin, Paeoniflorin, Chromatography, Chemistry, Verbascoside, High-performance liquid chromatography, Capsule, Stereochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of four constituents in Liuwei Dihuang Capsule by HPLC — Research Paper | ScholarLens