2009Journal of Dalian Fisheries UniversityRequires access

Detection of quinocetone residues in fishery products by high performance liquid chromatography method

Pan De-bo

Open publisher page 0 citations

Abstract

A method for detection of quinocetone residues in fishery products was developed by high performance liquid chromatography(HPLC) method coupled with ultraviolet detection.Samples were extracted by ethyl acetate and purified by n-hexane,and a standard linear response was observed for the quinoacetone levels from 0.02 μg/mL to 1.0 μg/mL with correlation coefficient of 0.9998.Average recoveries of the quinocetone varied from 81.2% to 107.0% and relative standard deviations ranged from 0.13% to 7.7%.The limits of detection were found to be 20 μg/kg.

About this research paper

What this paper is about

A method for detection of quinocetone residues in fishery products was developed by high performance liquid chromatography(HPLC) method coupled with ultraviolet detection.Samples were extracted by ethyl acetate and purified by n-hexane,and a standard linear response was observed for the quinoacetone levels from 0.02 μg/mL to 1.0 μg/mL with correlation coefficient of 0.9998.Average recoveries of the quinocetone varied from 81.2% to 107.0% and relative standard deviations ranged from 0.13% to 7.7%.The limits of detection were found to be 20 μg/kg.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for detection of quinocetone residues in fishery products was developed by high performance liquid chromatography(HPLC) method coupled with ultraviolet detection.Samples were extracted by ethyl acetate and purified by n-hexane,and a standard linear response was observed for the quinoacetone levels from 0.02 μg/mL to 1.0 μg/mL with correlation coefficient of 0.9998.Average recoveries of the quinocetone varied from 81.2% to 107.0% and relative standard deviations ranged from 0.13% to 7.7%.The limits of detection were found to be 20 μg/kg.

Key concepts: Chromatography, High-performance liquid chromatography, Detection limit, Residue (chemistry), Ethyl acetate, Hexane, Chemistry, Relative standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection of quinocetone residues in fishery products by high performance liquid chromatography method — Research Paper | ScholarLens