Small-incision transscleral sulcus fixation of posterior chamber intraocular three pieces of types lens implantation
He Ta
Abstract
He Ta
Abstract
Objective To study and assessment the effectiveness and feasibility of small-incision transscleral sulcus fixation with posterior chamber intraocular three pieces of types lens.Methods Forty-three patients(43 eyes) with zonule abnormity or posterior capsule rupture were performed intraocular lens implantation through corneal incision,and pre-fixed with polypropylene suture followed by three pieces of type lens foldable intraocular fixed in sulcus by injector.Results The uncorrected visual acuity of all operated eyes were improved.After 1 week,there were 12 eyes in 1.0,16 eyes in 0.6~0.8, 15 eyes in 0.4~0.6,and there were 16 eyes in 1.0,18 eyes in 0.6~0.8,9 eyes in 0.4~0.6 after 3 months.The mean astigmatism was 1.15D±0.75D(1 week) and 0.75D±0.35D(3 months) respectively,with the eye pressure was(16±3) mmHg(1 week) and(18±8)mmHg(3 months),and no statistical significant compared with pre-operation(P0.05).Besides, there were no significant severely complications intra-and post-operation.Conclusion It demonstrated that the small-incision transscleral sulcus fixation with posterior chamber intraocular three pieces of types lens had less complications,small astigmatism,which proved the potential to be widely applied.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To study and assessment the effectiveness and feasibility of small-incision transscleral sulcus fixation with posterior chamber intraocular three pieces of types lens.Methods Forty-three patients(43 eyes) with zonule abnormity or posterior capsule rupture were performed intraocular lens implantation through corneal incision,and pre-fixed with polypropylene suture followed by three pieces of type lens foldable intraocular fixed in sulcus by injector.Results The uncorrected visual acuity of all operated eyes were improved.After 1 week,there were 12 eyes in 1.0,16 eyes in 0.6~0.8, 15 eyes in 0.4~0.6,and there were 16 eyes in 1.0,18 eyes in 0.6~0.8,9 eyes in 0.4~0.6 after 3 months.The mean astigmatism was 1.15D±0.75D(1 week) and 0.75D±0.35D(3 months) respectively,with the eye pressure was(16±3) mmHg(1 week) and(18±8)mmHg(3 months),and no statistical significant compared with pre-operation(P0.05).Besides, there were no significant severely complications intra-and post-operation.Conclusion It demonstrated that the small-incision transscleral sulcus fixation with posterior chamber intraocular three pieces of types lens had less complications,small astigmatism,which proved the potential to be widely applied.
Key concepts: Medicine, Intraocular lens, Ophthalmology, Fixation (population genetics), Sulcus, Visual acuity, Intraocular pressure, Intraocular lenses