2009•Food Science and Technology InternationalRequires access

Research on determination of Jujuboside A in Semen Ziziphi spinosae milk drink

Zicheng Li

Open publisher page 1 citations

Abstract

A method for determination of Jujuboside A in Semen Ziziphi spinosae milk drink by RP-HPLC was established. The column is Kromasil ODS-1 C18(250 mm×4.6 mm, 5 μm). The mobile phase is acetonitrile- water (34∶66). The UV detector is set at 204 nm. The linear range of the determination is 0.070~0.70 mg/mL with the correlation coefficient of 0.999. The sample solution is stable within 8 h. The average recovery rate was 94.1% with RSD of 1.96% . The method is simple, accurate and specific. It is suitable for the determination of Jujuboside A in Semen Ziziphi spinosae milk drink.

About this research paper

What this paper is about

A method for determination of Jujuboside A in Semen Ziziphi spinosae milk drink by RP-HPLC was established. The column is Kromasil ODS-1 C18(250 mm×4.6 mm, 5 μm). The mobile phase is acetonitrile- water (34∶66). The UV detector is set at 204 nm. The linear range of the determination is 0.070~0.70 mg/mL with the correlation coefficient of 0.999. The sample solution is stable within 8 h. The average recovery rate was 94.1% with RSD of 1.96% . The method is simple, accurate and specific. It is suitable for the determination of Jujuboside A in Semen Ziziphi spinosae milk drink.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of Jujuboside A in Semen Ziziphi spinosae milk drink by RP-HPLC was established. The column is Kromasil ODS-1 C18(250 mm×4.6 mm, 5 μm). The mobile phase is acetonitrile- water (34∶66). The UV detector is set at 204 nm. The linear range of the determination is 0.070~0.70 mg/mL with the correlation coefficient of 0.999. The sample solution is stable within 8 h. The average recovery rate was 94.1% with RSD of 1.96% . The method is simple, accurate and specific. It is suitable for the determination of Jujuboside A in Semen Ziziphi spinosae milk drink.

Key concepts: Chromatography, Semen, Chemistry, Correlation coefficient, High-performance liquid chromatography, Linear relationship, Mathematics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on determination of Jujuboside A in Semen Ziziphi spinosae milk drink — Research Paper | ScholarLens