2012•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Lactic in Rat Serum by RP-HPLC

Dong Xiu

Open publisher page 0 citations

Abstract

The method for determination of lactic in rat serum was developed by reversed-phase high performance liquid chromatography(RP-HPLC) with ultraviolet detector.Protein in serum samples was precipitated by perchloric acid solution,and Eclipse plus C18 column was used with 5% methanol-water solution containing 0.2% phosphoric acid as the mobile phase at a flow rate of 0.8mL·min-1,and detection wavelength was 210nm,quantified by external standard method.Lactic had good linear in the range of 4.88×10-3—5g·L-1(r=0.9999),and the detection limit was 1.5×10-3g·L-1.The method is fast,sensitive with good precision.

About this research paper

What this paper is about

The method for determination of lactic in rat serum was developed by reversed-phase high performance liquid chromatography(RP-HPLC) with ultraviolet detector.Protein in serum samples was precipitated by perchloric acid solution,and Eclipse plus C18 column was used with 5% methanol-water solution containing 0.2% phosphoric acid as the mobile phase at a flow rate of 0.8mL·min-1,and detection wavelength was 210nm,quantified by external standard method.Lactic had good linear in the range of 4.88×10-3—5g·L-1(r=0.9999),and the detection limit was 1.5×10-3g·L-1.The method is fast,sensitive with good precision.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method for determination of lactic in rat serum was developed by reversed-phase high performance liquid chromatography(RP-HPLC) with ultraviolet detector.Protein in serum samples was precipitated by perchloric acid solution,and Eclipse plus C18 column was used with 5% methanol-water solution containing 0.2% phosphoric acid as the mobile phase at a flow rate of 0.8mL·min-1,and detection wavelength was 210nm,quantified by external standard method.Lactic had good linear in the range of 4.88×10-3—5g·L-1(r=0.9999),and the detection limit was 1.5×10-3g·L-1.The method is fast,sensitive with good precision.

Key concepts: Chromatography, Phosphoric acid, Chemistry, Perchloric acid, Detection limit, High-performance liquid chromatography, Lactic acid, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Lactic in Rat Serum by RP-HPLC — Research Paper | ScholarLens