Determination of Lactic Acid Content in Subcutaneous Micro-dialysis Fluid of Tumor-burdened Mice by HPLC
LI Qing-son
Abstract
LI Qing-son
Abstract
Objective: To establish a method for the determination of lactic acid content in subcutaneous micro-dialysis fluid of hepatoma-bearing mice by micro-dialysis combined with HPLC. Method: Micro-dialysis system was adopted to collect subcutaneous micro-dialysis fluid of normal mice and tumor-burdened mice for determining the content of lactic acid in subcutaneous micro-dialysis fluid by HPLC. The ZORBAX SB-Aq column( 4. 6 mm × 150 mm,5 μm) was used with the mobile phase of methanol-0. 1% phosphoric acid solution( 5∶ 95)at a flow rate of 1. 0 m L·min-1,the detection wavelength was 210 nm,and the column temperature was set at 30℃. Result: The linearity ranged between 20. 39-611. 6 mg·L-1with the average recovery rate of 97. 41% and RSD of 4. 1%. Conclusion: This method is simple,reliable,rapid and highly sensitive,it can accurately detect lactic acid content in dialyzate and provide a new way to detect lactic acid.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To establish a method for the determination of lactic acid content in subcutaneous micro-dialysis fluid of hepatoma-bearing mice by micro-dialysis combined with HPLC. Method: Micro-dialysis system was adopted to collect subcutaneous micro-dialysis fluid of normal mice and tumor-burdened mice for determining the content of lactic acid in subcutaneous micro-dialysis fluid by HPLC. The ZORBAX SB-Aq column( 4. 6 mm × 150 mm,5 μm) was used with the mobile phase of methanol-0. 1% phosphoric acid solution( 5∶ 95)at a flow rate of 1. 0 m L·min-1,the detection wavelength was 210 nm,and the column temperature was set at 30℃. Result: The linearity ranged between 20. 39-611. 6 mg·L-1with the average recovery rate of 97. 41% and RSD of 4. 1%. Conclusion: This method is simple,reliable,rapid and highly sensitive,it can accurately detect lactic acid content in dialyzate and provide a new way to detect lactic acid.
Key concepts: Phosphoric acid, Chromatography, Lactic acid, Dialysis, High-performance liquid chromatography, Chemistry, Dialysis tubing, Recovery rate