2007•Chinese Journal of Clinical NeurosciencesRequires access

Embolizing Arteriovenous Malformation or Dural Arteriovenous Fistular with Onyx-34 (13 CasesReport)

Song Dong

Open publisher page 0 citations

Abstract

Aim:To introduce the experience of embolized arteriovenous malformation (AVM) or dural arteriovenous fistular (DAVF) with Onyx-34 for 13 cases. Methods: Of 13 cases from AVM or DAVF, 6 cases were AVM and 7 cases DAVF. 10 cases were embolized with Onyx-34 only and 3 cases Onyx-34 combined with coils. Results:13 cases had no complications due to the embolization with Onyx-34. 6 of 13 cases from AVM,the ratio of embolization was 100% with Onyx-34 for 5 cases from AVM. 7 cases suffered from DAVF were cured by embolization with Onyx-34. The time of injecting Onyx-34 was 54 seconds average. The quantity of Onyx-34 for AVM is 2.2ml average and 0.5ml average for DAVF respectively. Conclusion: Onyx-34 is one of better embolizing materials for AVM or DAVF.

About this research paper

What this paper is about

Aim:To introduce the experience of embolized arteriovenous malformation (AVM) or dural arteriovenous fistular (DAVF) with Onyx-34 for 13 cases. Methods: Of 13 cases from AVM or DAVF, 6 cases were AVM and 7 cases DAVF. 10 cases were embolized with Onyx-34 only and 3 cases Onyx-34 combined with coils. Results:13 cases had no complications due to the embolization with Onyx-34. 6 of 13 cases from AVM,the ratio of embolization was 100% with Onyx-34 for 5 cases from AVM. 7 cases suffered from DAVF were cured by embolization with Onyx-34. The time of injecting Onyx-34 was 54 seconds average. The quantity of Onyx-34 for AVM is 2.2ml average and 0.5ml average for DAVF respectively. Conclusion: Onyx-34 is one of better embolizing materials for AVM or DAVF.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim:To introduce the experience of embolized arteriovenous malformation (AVM) or dural arteriovenous fistular (DAVF) with Onyx-34 for 13 cases. Methods: Of 13 cases from AVM or DAVF, 6 cases were AVM and 7 cases DAVF. 10 cases were embolized with Onyx-34 only and 3 cases Onyx-34 combined with coils. Results:13 cases had no complications due to the embolization with Onyx-34. 6 of 13 cases from AVM,the ratio of embolization was 100% with Onyx-34 for 5 cases from AVM. 7 cases suffered from DAVF were cured by embolization with Onyx-34. The time of injecting Onyx-34 was 54 seconds average. The quantity of Onyx-34 for AVM is 2.2ml average and 0.5ml average for DAVF respectively. Conclusion: Onyx-34 is one of better embolizing materials for AVM or DAVF.

Key concepts: Arteriovenous malformation, Medicine, Embolization, Radiology, Arteriovenous fistula, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Embolizing Arteriovenous Malformation or Dural Arteriovenous Fistular with Onyx-34 (13 CasesReport) — Research Paper | ScholarLens