2000•PubMedRequires access

[Determination of cinnamaldehyde in Guizhi by HPLC].

J P Luo, Z S Zhang, Cui Tian, X M Li

Open publisher page 3 citations

Abstract

OBJECTIVE: To establish a HPLC method for the determination of cinnamaldehyde in Guizhi. METHOD: Cinnamaldehyde was separated by a Kromasil C18 column (4.6 mm x 200 mm) with a mobile phase of acetonitrile-0.1% phosphoric acid solution(48:52) and an UV detection wavelength of 285 nm. RESULT: The calibration curve was linear in the range of 0.004-0.02 microliter.ml-1, with a correlation coefficient of 0.9996. The average recovery was 100.7%(n = 5), and RSD 0.3%(n = 6). CONCLUSION: The method is simple and accurate.

About this research paper

What this paper is about

OBJECTIVE: To establish a HPLC method for the determination of cinnamaldehyde in Guizhi. METHOD: Cinnamaldehyde was separated by a Kromasil C18 column (4.6 mm x 200 mm) with a mobile phase of acetonitrile-0.1% phosphoric acid solution(48:52) and an UV detection wavelength of 285 nm. RESULT: The calibration curve was linear in the range of 0.004-0.02 microliter.ml-1, with a correlation coefficient of 0.9996. The average recovery was 100.7%(n = 5), and RSD 0.3%(n = 6). CONCLUSION: The method is simple and accurate.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish a HPLC method for the determination of cinnamaldehyde in Guizhi. METHOD: Cinnamaldehyde was separated by a Kromasil C18 column (4.6 mm x 200 mm) with a mobile phase of acetonitrile-0.1% phosphoric acid solution(48:52) and an UV detection wavelength of 285 nm. RESULT: The calibration curve was linear in the range of 0.004-0.02 microliter.ml-1, with a correlation coefficient of 0.9996. The average recovery was 100.7%(n = 5), and RSD 0.3%(n = 6). CONCLUSION: The method is simple and accurate.

Key concepts: Cinnamaldehyde, Calibration curve, Chromatography, Phosphoric acid, High-performance liquid chromatography, Correlation coefficient, Chemistry, Linear correlation

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of cinnamaldehyde in Guizhi by HPLC]. — Research Paper | ScholarLens