Determination of Mangiferin, Jateorrhizine, Palmatine, Berberine, Cinnamic Acid, and Cinnamaldehyde in the Traditional Chinese Medicinal Preparation Zi-Shen Pill by High-Performance Liquid Chromatography
Ronghua Dai, K. Li, Qing Li, K. Bi
Abstract
Ronghua Dai, K. Li, Qing Li, K. Bi
Abstract
High-performance liquid chromatography is employed to determine the contents of six marker components such as mangiferin, jateorrhizine, palmatine, berberine, cinnamic acid, and cinnamaldehyde in the traditional Chinese medicinal preparation Zi-Shen pill. The separation is performed on a C(18) column by stepwise gradient elution with water (0.2%, v/v, triethylamine adjusted to pH 4 with phosphoric acid)-methanol-acetonitrile (0.01 min, 98:0:2; 20 min, 80:5:15; 30 min, 65:13:22; and 55 min, 65:13:22) as the mobile phase at a flow rate of 0.9 mL/min, with UV detection at 280 nm. Six regression equations show good linear relationships between the peak area of each marker and concentration. The recoveries of the markers listed are 95.5%, 98.3%, 96.8%, 99.5%, 101.7%, and 102.1%, respectively. The repeatability and reproducibility (relative standard deviation) of the method are less than 2.5% and 3.3%, respectively.
OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
High-performance liquid chromatography is employed to determine the contents of six marker components such as mangiferin, jateorrhizine, palmatine, berberine, cinnamic acid, and cinnamaldehyde in the traditional Chinese medicinal preparation Zi-Shen pill. The separation is performed on a C(18) column by stepwise gradient elution with water (0.2%, v/v, triethylamine adjusted to pH 4 with phosphoric acid)-methanol-acetonitrile (0.01 min, 98:0:2; 20 min, 80:5:15; 30 min, 65:13:22; and 55 min, 65:13:22) as the mobile phase at a flow rate of 0.9 mL/min, with UV detection at 280 nm. Six regression equations show good linear relationships between the peak area of each marker and concentration. The recoveries of the markers listed are 95.5%, 98.3%, 96.8%, 99.5%, 101.7%, and 102.1%, respectively. The repeatability and reproducibility (relative standard deviation) of the method are less than 2.5% and 3.3%, respectively.
Key concepts: Chemistry, Chromatography, Palmatine, Berberine, Repeatability, Cinnamaldehyde, High-performance liquid chromatography, Cinnamic acid