2002Journal of the Korean Ophthalmological SocietyRequires access

Accuracy of Orbscan Pachymetry Measurements and Ultrasonic Pachymetry before and after LASIK with Orbscan II$^{\circledR}$ Topography

Sung‐Hyun Kim, Jaeho Cho, Byung‐Joo Song

Open publisher page 3 citations

Abstract

Purpose : To assess the the accuracy and variability in pachymetry measurements obtained by Orbscan and ultrasonic pachymeter in laser in situ keratomileusis (LASIK). Methods : Thirty two eyes of 16 patients before LASIK were measured by ultrasonic pachymeter and Orbscan. Thirty eyes of 16 patients that had LASIK were measured by ultrasonic pachymeter and Orbscan postoperatively. The theoretical residual corneal thickness was compared to measurements by both instruments in eyes that had LASIK procedures. Results: The ultrasound pachymeter measurements (543.824.2 ,urn) were thicker than the Orbscan pachymetry measurements, (541.224.9 ,urn) by mean of 2.77.4,urn (SD), preoperatively. But this is not statistically significant (p>O.05). Postoperatively, the ultrsound measurements were consistent with theoretical residual corneal thickness, 461.837.4,urn versus 467.930.71 ,urn (p=O.064), while Orbscan measurements were statistically less than the theoretical residual corneal thickness, 433.248.75 ,urn versus 464.3233.4,urn (p

About this research paper

What this paper is about

Purpose : To assess the the accuracy and variability in pachymetry measurements obtained by Orbscan and ultrasonic pachymeter in laser in situ keratomileusis (LASIK). Methods : Thirty two eyes of 16 patients before LASIK were measured by ultrasonic pachymeter and Orbscan. Thirty eyes of 16 patients that had LASIK were measured by ultrasonic pachymeter and Orbscan postoperatively. The theoretical residual corneal thickness was compared to measurements by both instruments in eyes that had LASIK procedures. Results: The ultrasound pachymeter measurements (543.824.2 ,urn) were thicker than the Orbscan pachymetry measurements, (541.224.9 ,urn) by mean of 2.77.4,urn (SD), preoperatively. But this is not statistically significant (p>O.05). Postoperatively, the ultrsound measurements were consistent with theoretical residual corneal thickness, 461.837.4,urn versus 467.930.71 ,urn (p=O.064), while Orbscan measurements were statistically less than the theoretical residual corneal thickness, 433.248.75 ,urn versus 464.3233.4,urn (p

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose : To assess the the accuracy and variability in pachymetry measurements obtained by Orbscan and ultrasonic pachymeter in laser in situ keratomileusis (LASIK). Methods : Thirty two eyes of 16 patients before LASIK were measured by ultrasonic pachymeter and Orbscan. Thirty eyes of 16 patients that had LASIK were measured by ultrasonic pachymeter and Orbscan postoperatively. The theoretical residual corneal thickness was compared to measurements by both instruments in eyes that had LASIK procedures. Results: The ultrasound pachymeter measurements (543.824.2 ,urn) were thicker than the Orbscan pachymetry measurements, (541.224.9 ,urn) by mean of 2.77.4,urn (SD), preoperatively. But this is not statistically significant (p>O.05). Postoperatively, the ultrsound measurements were consistent with theoretical residual corneal thickness, 461.837.4,urn versus 467.930.71 ,urn (p=O.064), while Orbscan measurements were statistically less than the theoretical residual corneal thickness, 433.248.75 ,urn versus 464.3233.4,urn (p

Key concepts: LASIK, Keratomileusis, Medicine, Ophthalmology, Residual, Ultrasonic sensor, Ultrasound, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy of Orbscan Pachymetry Measurements and Ultrasonic Pachymetry before and after LASIK with Orbscan II$^{\circledR}$ Topography — Research Paper | ScholarLens