1999•Fuzhou daxue xuebao. Ziran kexue banRequires access

Study on the New Indicative Reaction for Catalytic Kinetic Determination of Trace Copper(II)

Gao Shui-ying

Open publisher page 1 citations

Abstract

A new catalytic kinetic spectrophotometric method for determination of trace copper(Ⅱ) based on catalytic effect of Cu(Ⅱ) on the chromogenic reaction resulted from the oxidation of guaiacol with ammonium persulfate in boric acid and sodium hydroxide buffer medium has been investigated.The linear range is 0~7 2μg/L,and detection limit is 48 6ng/L.This method has been used to determine copper (Ⅱ) in offscum of plumbean-zinc mine with satisfactory results.

About this research paper

What this paper is about

A new catalytic kinetic spectrophotometric method for determination of trace copper(Ⅱ) based on catalytic effect of Cu(Ⅱ) on the chromogenic reaction resulted from the oxidation of guaiacol with ammonium persulfate in boric acid and sodium hydroxide buffer medium has been investigated.The linear range is 0~7 2μg/L,and detection limit is 48 6ng/L.This method has been used to determine copper (Ⅱ) in offscum of plumbean-zinc mine with satisfactory results.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new catalytic kinetic spectrophotometric method for determination of trace copper(Ⅱ) based on catalytic effect of Cu(Ⅱ) on the chromogenic reaction resulted from the oxidation of guaiacol with ammonium persulfate in boric acid and sodium hydroxide buffer medium has been investigated.The linear range is 0~7 2μg/L,and detection limit is 48 6ng/L.This method has been used to determine copper (Ⅱ) in offscum of plumbean-zinc mine with satisfactory results.

Key concepts: Copper, Chemistry, Catalysis, Ammonium persulfate, Inorganic chemistry, Detection limit, Guaiacol, Chromogenic

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the New Indicative Reaction for Catalytic Kinetic Determination of Trace Copper(II) — Research Paper | ScholarLens