2005Zhonghua jianyan yixue zazhiRequires access

The applied research of automatic nucleated red blood cell count in peripheral blood by blood cell analyzer

LI Jian-yin

Open publisher page 0 citations

Abstract

Objective To evaluate the characteristics of an automatic nucleated red blood cell (NRBC) count by blood cell analyzer and research its clinical applications.Method The peripheral blood NRBC of 115 patients suffering from hematological diseases or other diseases were counted by both Sysmex XE-21000 automatic blood cell analyzer and manual method with microscope.Results There was a very good correlation between the manual and automatic method (r0.97) . No significant difference was observed between the counting results of two methods(P=0.201 8). The average intra lot CV of absolute NRBC count of high, medium and low value was below 6.5%. The NRBC counts was rather linear(r=0.999 8) in the range of 0~15 ×10~9/L. Both the sensitivity and negative prediction value were 100%. When the peripheral NRBC increases, the counting of WBC was significantly higher than the value obtained when the NRBC was depleted (P=0.016 8).Conclusions The NRBC counting by the XE-2100 was sensitive, accurate and reliable. The XE-2000 can measure the WBC accurately in sample with increased NRBC. Besides patients with hematological diseases, such as leukemia, anemia etc, the NRBC could also be observed in other patients with non hematological diseases, e.g. cancer chemotherapy. The automatic evaluation of peripheral NRBC maybe helpful to the screening and diagnosis of some hematological and non hematological diseases.

About this research paper

What this paper is about

Objective To evaluate the characteristics of an automatic nucleated red blood cell (NRBC) count by blood cell analyzer and research its clinical applications.Method The peripheral blood NRBC of 115 patients suffering from hematological diseases or other diseases were counted by both Sysmex XE-21000 automatic blood cell analyzer and manual method with microscope.Results There was a very good correlation between the manual and automatic method (r0.97) . No significant difference was observed between the counting results of two methods(P=0.201 8). The average intra lot CV of absolute NRBC count of high, medium and low value was below 6.5%. The NRBC counts was rather linear(r=0.999 8) in the range of 0~15 ×10~9/L. Both the sensitivity and negative prediction value were 100%. When the peripheral NRBC increases, the counting of WBC was significantly higher than the value obtained when the NRBC was depleted (P=0.016 8).Conclusions The NRBC counting by the XE-2100 was sensitive, accurate and reliable. The XE-2000 can measure the WBC accurately in sample with increased NRBC. Besides patients with hematological diseases, such as leukemia, anemia etc, the NRBC could also be observed in other patients with non hematological diseases, e.g. cancer chemotherapy. The automatic evaluation of peripheral NRBC maybe helpful to the screening and diagnosis of some hematological and non hematological diseases.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the characteristics of an automatic nucleated red blood cell (NRBC) count by blood cell analyzer and research its clinical applications.Method The peripheral blood NRBC of 115 patients suffering from hematological diseases or other diseases were counted by both Sysmex XE-21000 automatic blood cell analyzer and manual method with microscope.Results There was a very good correlation between the manual and automatic method (r0.97) . No significant difference was observed between the counting results of two methods(P=0.201 8). The average intra lot CV of absolute NRBC count of high, medium and low value was below 6.5%. The NRBC counts was rather linear(r=0.999 8) in the range of 0~15 ×10~9/L. Both the sensitivity and negative prediction value were 100%. When the peripheral NRBC increases, the counting of WBC was significantly higher than the value obtained when the NRBC was depleted (P=0.016 8).Conclusions The NRBC counting by the XE-2100 was sensitive, accurate and reliable. The XE-2000 can measure the WBC accurately in sample with increased NRBC. Besides patients with hematological diseases, such as leukemia, anemia etc, the NRBC could also be observed in other patients with non hematological diseases, e.g. cancer chemotherapy. The automatic evaluation of peripheral NRBC maybe helpful to the screening and diagnosis of some hematological and non hematological diseases.

Key concepts: Nucleated Red Blood Cell, Peripheral blood, Blood cell, Spectrum analyzer, Medicine, Anemia, Hematology analyzer, Red blood cell

Related papers

Back to paper searchBrowse research topicsOriginal source
The applied research of automatic nucleated red blood cell count in peripheral blood by blood cell analyzer — Research Paper | ScholarLens