2011•Guangzhou Chemical IndustryRequires access

Research on the Rapid Determination of COD in Wastewater by the UV-spectrometry

Haifeng Chen

Open publisher page 0 citations

Abstract

On the basis of potassium dichromate method,the determination of COD in wastewaters was investigated by the ways of increasing the relative amount of the catalysts and the oxidants which shortened time greatly.The spectrometry was used to replace the titration with ammonium ferrous sulfate and the maximum absorptiom wavelength was 349 nm.The results showed that the method met determination requirements which water COD ranged 10~700 mg·L-1.The relative standard deviation was less than 2.6%,and showed good precision and accuracy.

About this research paper

What this paper is about

On the basis of potassium dichromate method,the determination of COD in wastewaters was investigated by the ways of increasing the relative amount of the catalysts and the oxidants which shortened time greatly.The spectrometry was used to replace the titration with ammonium ferrous sulfate and the maximum absorptiom wavelength was 349 nm.The results showed that the method met determination requirements which water COD ranged 10~700 mg·L-1.The relative standard deviation was less than 2.6%,and showed good precision and accuracy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

On the basis of potassium dichromate method,the determination of COD in wastewaters was investigated by the ways of increasing the relative amount of the catalysts and the oxidants which shortened time greatly.The spectrometry was used to replace the titration with ammonium ferrous sulfate and the maximum absorptiom wavelength was 349 nm.The results showed that the method met determination requirements which water COD ranged 10~700 mg·L-1.The relative standard deviation was less than 2.6%,and showed good precision and accuracy.

Key concepts: Potassium dichromate, Relative standard deviation, Wastewater, Titration, Chemistry, Ferrous, Ammonium sulfate, Ammonium

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on the Rapid Determination of COD in Wastewater by the UV-spectrometry — Research Paper | ScholarLens