2004Journal of Gansu SciencesRequires access

Rapid Determination of Chemical Oxygen Demand By Sulfuric-Acid Digestion and Visible Spectrometry

Yanfeng Li

Open publisher page 1 citations

Abstract

A rapid and simple method based on visible spectrometric procedure is proposed for the determination of COD in wastewater treatment system. It is an improvement of standard method to determine COD, i.e. determination of excess dichromate (Cr -2O + {2- } -7) by visible spectrometry at 442 nm. The absorbance value (A) of Cr -2O + {2- } -7 and the concentration of COD have linear relation by computer analogy, so COD is determined indirectly in this way. Some influencing factors, such as the refluxing time, the amount of wastewater sample and potassium dichromate, sulfuric acid concentration are investigated, respectively. The result shows that when the concentration of COD in wastewater sample is in the range of 65~(650 mg·L + {-1 }), the results obtained by using the method presented exhibit good agreement with those given by the standard method of COD determination, and the relative error is less than 5.0%. The viability of this method is demonstrated by analyzing two kinds of synthetic wastewater and five kinds of industrial wastewater, and it proves to be a rapid and accurate method for COD determination.

About this research paper

What this paper is about

A rapid and simple method based on visible spectrometric procedure is proposed for the determination of COD in wastewater treatment system. It is an improvement of standard method to determine COD, i.e. determination of excess dichromate (Cr -2O + {2- } -7) by visible spectrometry at 442 nm. The absorbance value (A) of Cr -2O + {2- } -7 and the concentration of COD have linear relation by computer analogy, so COD is determined indirectly in this way. Some influencing factors, such as the refluxing time, the amount of wastewater sample and potassium dichromate, sulfuric acid concentration are investigated, respectively. The result shows that when the concentration of COD in wastewater sample is in the range of 65~(650 mg·L + {-1 }), the results obtained by using the method presented exhibit good agreement with those given by the standard method of COD determination, and the relative error is less than 5.0%. The viability of this method is demonstrated by analyzing two kinds of synthetic wastewater and five kinds of industrial wastewater, and it proves to be a rapid and accurate method for COD determination.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid and simple method based on visible spectrometric procedure is proposed for the determination of COD in wastewater treatment system. It is an improvement of standard method to determine COD, i.e. determination of excess dichromate (Cr -2O + {2- } -7) by visible spectrometry at 442 nm. The absorbance value (A) of Cr -2O + {2- } -7 and the concentration of COD have linear relation by computer analogy, so COD is determined indirectly in this way. Some influencing factors, such as the refluxing time, the amount of wastewater sample and potassium dichromate, sulfuric acid concentration are investigated, respectively. The result shows that when the concentration of COD in wastewater sample is in the range of 65~(650 mg·L + {-1 }), the results obtained by using the method presented exhibit good agreement with those given by the standard method of COD determination, and the relative error is less than 5.0%. The viability of this method is demonstrated by analyzing two kinds of synthetic wastewater and five kinds of industrial wastewater, and it proves to be a rapid and accurate method for COD determination.

Key concepts: Potassium dichromate, Wastewater, Chemical oxygen demand, Sulfuric acid, Chemistry, Absorbance, Detection limit, Relative standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid Determination of Chemical Oxygen Demand By Sulfuric-Acid Digestion and Visible Spectrometry — Research Paper | ScholarLens