Discussion on the Determination Method of COD in High Chloride Wastewater
Fen Wang
Abstract
Fen Wang
Abstract
After acid-base neutralization and pressure filtration, the wastewater of printing plates contains a large amount of chloride ions(20000mg/L) and 200 to 400mg/L COD. According to the traditional GB method of the reflow technology within two hours, the detecting precision of COD can't be achieved,and it is a waste of time and drugs. The national standard KI absorption correction method is not suitable for water samples which contain more than 50mg/L COD. The contents of COD in water samples with 10000mg/L chloride ions and 200 to 500mg/L COD are determined by digestion method through 30% mercury sulfate-sulfuric acid solution as a sequestering agent and 0.1M potassium dichromate as an oxidant within one hour. The relative standard deviation is below 2.6%, and the recovery of standard addition is about 105%, so the result is very satisfactory. The problem of measuring the amount of COD in the wastewater from printing plates(PS plate, CTP plate) has been solved. Then a reference for determination of the wastewater in oil, chemical industries was provided.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
After acid-base neutralization and pressure filtration, the wastewater of printing plates contains a large amount of chloride ions(20000mg/L) and 200 to 400mg/L COD. According to the traditional GB method of the reflow technology within two hours, the detecting precision of COD can't be achieved,and it is a waste of time and drugs. The national standard KI absorption correction method is not suitable for water samples which contain more than 50mg/L COD. The contents of COD in water samples with 10000mg/L chloride ions and 200 to 500mg/L COD are determined by digestion method through 30% mercury sulfate-sulfuric acid solution as a sequestering agent and 0.1M potassium dichromate as an oxidant within one hour. The relative standard deviation is below 2.6%, and the recovery of standard addition is about 105%, so the result is very satisfactory. The problem of measuring the amount of COD in the wastewater from printing plates(PS plate, CTP plate) has been solved. Then a reference for determination of the wastewater in oil, chemical industries was provided.
Key concepts: Wastewater, Potassium dichromate, Chloride, Chemistry, Sulfuric acid, Relative standard deviation, Pulp and paper industry, Chromatography