2012Zhongguo shiyan fangjixue zazhiRequires access

Simultaneous Determination Muscone,Borneol, Camphor and Isoborneol in Xingnaojing Injection by GC

Meng Dajun

Open publisher page 0 citations

Abstract

Objective:To establish the simultaneous determination of muscone,borneol,camphor and isoborneol in Xingnaojing Injection.Method: The GC system consisted of capillary column,DB-FFAP-30M;FID as the detector.The column temperature was programmed from 85 ℃ to 185 ℃ at 5 ℃·min-1,then to 215 ℃ at 20 ℃·min-1,to 230 ℃ at 1 ℃·min-1(holding 5 minutes).The inlet temperature was 230 ℃.The detect temperature was 240 ℃.Nitrogen was used as carrying gas(2.5 mL·min-1).The split ratio was 15∶1;injection volume was 1 μL.The external standard method was employed.Result: Muscone,borneol,camphor and isoborneol in Xingnaojing Injection have been separated well under the same chromatographic condition.Muscone,borneol,camphor and isoborneol are in the determination of a good linear relationship within the scope.Recovery rate of the determination method all corresponded to the experimental standard.Conclusion: The method is simple,sensitive,accurate,separable and reproducible,and can be used to control the quality of Xingnaojing Injection.

About this research paper

What this paper is about

Objective:To establish the simultaneous determination of muscone,borneol,camphor and isoborneol in Xingnaojing Injection.Method: The GC system consisted of capillary column,DB-FFAP-30M;FID as the detector.The column temperature was programmed from 85 ℃ to 185 ℃ at 5 ℃·min-1,then to 215 ℃ at 20 ℃·min-1,to 230 ℃ at 1 ℃·min-1(holding 5 minutes).The inlet temperature was 230 ℃.The detect temperature was 240 ℃.Nitrogen was used as carrying gas(2.5 mL·min-1).The split ratio was 15∶1;injection volume was 1 μL.The external standard method was employed.Result: Muscone,borneol,camphor and isoborneol in Xingnaojing Injection have been separated well under the same chromatographic condition.Muscone,borneol,camphor and isoborneol are in the determination of a good linear relationship within the scope.Recovery rate of the determination method all corresponded to the experimental standard.Conclusion: The method is simple,sensitive,accurate,separable and reproducible,and can be used to control the quality of Xingnaojing Injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish the simultaneous determination of muscone,borneol,camphor and isoborneol in Xingnaojing Injection.Method: The GC system consisted of capillary column,DB-FFAP-30M;FID as the detector.The column temperature was programmed from 85 ℃ to 185 ℃ at 5 ℃·min-1,then to 215 ℃ at 20 ℃·min-1,to 230 ℃ at 1 ℃·min-1(holding 5 minutes).The inlet temperature was 230 ℃.The detect temperature was 240 ℃.Nitrogen was used as carrying gas(2.5 mL·min-1).The split ratio was 15∶1;injection volume was 1 μL.The external standard method was employed.Result: Muscone,borneol,camphor and isoborneol in Xingnaojing Injection have been separated well under the same chromatographic condition.Muscone,borneol,camphor and isoborneol are in the determination of a good linear relationship within the scope.Recovery rate of the determination method all corresponded to the experimental standard.Conclusion: The method is simple,sensitive,accurate,separable and reproducible,and can be used to control the quality of Xingnaojing Injection.

Key concepts: Borneol, Camphor, Chromatography, Chemistry, Flumazenil, Diluent, Medicine, Organic chemistry