2014Journal of Hunan UniversityRequires access

Seismic Collapse Fragility Analysis of the 3D Parking Structure with Alternation Story-height Truss Lateral-load-resisting System

HE Yong-ju

Open publisher page 0 citations

Abstract

The seismic collapse-resistant capacity of the three-dimensional(3D)parking structure with alternation story-height truss lateral-load-resisting system was evaluated by IDA-based seismic fragility analysis method.The structural collapse process and mechanism under earthquake were analyzed.The seismic collapse-resistant capacities of the structure under one-directional and bi-directional earthquakes were compared.And the comparison of the seismic collapse-resistant capacities and collapse margin ratios of the structures with different floors was carried out.The result has shown that the seismic collapse-resistant performance of this kind of 3Dparking structure is very good,and the first storey is the weak storey.The collapse probability increases with the increase of the storey count of the structure,and then the seismic performance becomes weak.However,the collapse margin ratio of the structure does not always decrease with the increase of the storey count of the structure.It is recommended that the provision of the height-width ratio in the current design code of building structure can be broken in the design of this kind of 3Dparking structure.

About this research paper

What this paper is about

The seismic collapse-resistant capacity of the three-dimensional(3D)parking structure with alternation story-height truss lateral-load-resisting system was evaluated by IDA-based seismic fragility analysis method.The structural collapse process and mechanism under earthquake were analyzed.The seismic collapse-resistant capacities of the structure under one-directional and bi-directional earthquakes were compared.And the comparison of the seismic collapse-resistant capacities and collapse margin ratios of the structures with different floors was carried out.The result has shown that the seismic collapse-resistant performance of this kind of 3Dparking structure is very good,and the first storey is the weak storey.The collapse probability increases with the increase of the storey count of the structure,and then the seismic performance becomes weak.However,the collapse margin ratio of the structure does not always decrease with the increase of the storey count of the structure.It is recommended that the provision of the height-width ratio in the current design code of building structure can be broken in the design of this kind of 3Dparking structure.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The seismic collapse-resistant capacity of the three-dimensional(3D)parking structure with alternation story-height truss lateral-load-resisting system was evaluated by IDA-based seismic fragility analysis method.The structural collapse process and mechanism under earthquake were analyzed.The seismic collapse-resistant capacities of the structure under one-directional and bi-directional earthquakes were compared.And the comparison of the seismic collapse-resistant capacities and collapse margin ratios of the structures with different floors was carried out.The result has shown that the seismic collapse-resistant performance of this kind of 3Dparking structure is very good,and the first storey is the weak storey.The collapse probability increases with the increase of the storey count of the structure,and then the seismic performance becomes weak.However,the collapse margin ratio of the structure does not always decrease with the increase of the storey count of the structure.It is recommended that the provision of the height-width ratio in the current design code of building structure can be broken in the design of this kind of 3Dparking structure.

Key concepts: Fragility, Truss, Structural engineering, Geology, Alternation (linguistics), Seismic loading, Seismic analysis, Seismology

Related papers

Back to paper searchBrowse research topicsOriginal source
Seismic Collapse Fragility Analysis of the 3D Parking Structure with Alternation Story-height Truss Lateral-load-resisting System — Research Paper | ScholarLens