2011Dizhen gongcheng yu gongcheng zhendongRequires access

Study on the seismic collapse resistance of RC frame structures with equal spans in zones with seismic intensity VII

Shi Wei

Open publisher page 0 citations

Abstract

The seismic design of Chinese building structures is mostly depended on the structural elemental loading capacity design under minor earthquake and the detailed design to ensure the deformation capacity.However,it is lack of quantitative analysis of seismic collapse resistance under severe earthquake.And the actual seismic damage shows that even for the same structural types,the global structural parameters will greatly influence the seismic collapse resistances.Therefore,this paper designs 24 RC frame structures in zones with seismic intensity Ⅶ according to the Chinese Seismic Design Code,which have different spans,storey heights and storey number.Incremental dynamic analysis is performed for the structures to assess their seismic collapse resistance.The result shows that global structural parameters,especially the span and the storey number,have a great influence on the seismic collapse resistance.

About this research paper

What this paper is about

The seismic design of Chinese building structures is mostly depended on the structural elemental loading capacity design under minor earthquake and the detailed design to ensure the deformation capacity.However,it is lack of quantitative analysis of seismic collapse resistance under severe earthquake.And the actual seismic damage shows that even for the same structural types,the global structural parameters will greatly influence the seismic collapse resistances.Therefore,this paper designs 24 RC frame structures in zones with seismic intensity Ⅶ according to the Chinese Seismic Design Code,which have different spans,storey heights and storey number.Incremental dynamic analysis is performed for the structures to assess their seismic collapse resistance.The result shows that global structural parameters,especially the span and the storey number,have a great influence on the seismic collapse resistance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The seismic design of Chinese building structures is mostly depended on the structural elemental loading capacity design under minor earthquake and the detailed design to ensure the deformation capacity.However,it is lack of quantitative analysis of seismic collapse resistance under severe earthquake.And the actual seismic damage shows that even for the same structural types,the global structural parameters will greatly influence the seismic collapse resistances.Therefore,this paper designs 24 RC frame structures in zones with seismic intensity Ⅶ according to the Chinese Seismic Design Code,which have different spans,storey heights and storey number.Incremental dynamic analysis is performed for the structures to assess their seismic collapse resistance.The result shows that global structural parameters,especially the span and the storey number,have a great influence on the seismic collapse resistance.

Key concepts: Seismic analysis, Incremental Dynamic Analysis, Seismic resistance, Structural engineering, Seismic zone, Seismology, Environmental Seismic Intensity scale, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the seismic collapse resistance of RC frame structures with equal spans in zones with seismic intensity VII — Research Paper | ScholarLens