2007Science and Technology of Cereals,oils and FoodsRequires access

Determination of the selenium content in selenium-enriched malt by hydride generation atomic fluorescence spectrometry

Zhao Hong-jin

Open publisher page 0 citations

Abstract

A method for the determination of selenium from selenium-enriched malt by hydride generation atomic fluorescence spectrometry(HG-AFS) has been developed.The effects of the instrumental and chemical parameters on atomic fluorescence signal of selenium were discussed and optimum conditions were recommended.The effects of digest reagents on digestion of samples and the interference from foreign ions on selenium were briefly discussed.Under the optimum conditions,the detection limit for selenium was 0.167μg/L,the relative standard deviation was 1.203%,and the liner ranger was 0~100μg/L.A total selenium content of(11.729~)32.746μg/g was detected from selenium-enriched malt by this method,and the recovery rate is(94.1%~101.6%).

About this research paper

What this paper is about

A method for the determination of selenium from selenium-enriched malt by hydride generation atomic fluorescence spectrometry(HG-AFS) has been developed.The effects of the instrumental and chemical parameters on atomic fluorescence signal of selenium were discussed and optimum conditions were recommended.The effects of digest reagents on digestion of samples and the interference from foreign ions on selenium were briefly discussed.Under the optimum conditions,the detection limit for selenium was 0.167μg/L,the relative standard deviation was 1.203%,and the liner ranger was 0~100μg/L.A total selenium content of(11.729~)32.746μg/g was detected from selenium-enriched malt by this method,and the recovery rate is(94.1%~101.6%).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of selenium from selenium-enriched malt by hydride generation atomic fluorescence spectrometry(HG-AFS) has been developed.The effects of the instrumental and chemical parameters on atomic fluorescence signal of selenium were discussed and optimum conditions were recommended.The effects of digest reagents on digestion of samples and the interference from foreign ions on selenium were briefly discussed.Under the optimum conditions,the detection limit for selenium was 0.167μg/L,the relative standard deviation was 1.203%,and the liner ranger was 0~100μg/L.A total selenium content of(11.729~)32.746μg/g was detected from selenium-enriched malt by this method,and the recovery rate is(94.1%~101.6%).

Key concepts: Selenium, Chemistry, Hydride, Detection limit, Reagent, Analytical Chemistry (journal), Mass spectrometry, Fluorescence spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of the selenium content in selenium-enriched malt by hydride generation atomic fluorescence spectrometry — Research Paper | ScholarLens