2008Journal of Analytical ScienceRequires access

Determination of Trace Elements in Sargassum fusiforme by Microwave Digestion ICP-AES

Zhan Xiu-ming

Open publisher page 0 citations

Abstract

The paper described the determination of six elements(Fe,Mg,Ca,Ba, Mn and Al) in Sargassum fusiforme by ICP-AES.The Sargassum fusiforme sample was digested by microwave and the effect of acid medium on the digestion was studied.Under the optimal conditions,the detection limits of the six elements are in the range of 0.0005~0.01 μg/mL with the RSD≤2.6%.The recoveries are in the range of 95.7%~103.5%.The experimental results showed that the developed method is easy,rapid and accuracy.

About this research paper

What this paper is about

The paper described the determination of six elements(Fe,Mg,Ca,Ba, Mn and Al) in Sargassum fusiforme by ICP-AES.The Sargassum fusiforme sample was digested by microwave and the effect of acid medium on the digestion was studied.Under the optimal conditions,the detection limits of the six elements are in the range of 0.0005~0.01 μg/mL with the RSD≤2.6%.The recoveries are in the range of 95.7%~103.5%.The experimental results showed that the developed method is easy,rapid and accuracy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The paper described the determination of six elements(Fe,Mg,Ca,Ba, Mn and Al) in Sargassum fusiforme by ICP-AES.The Sargassum fusiforme sample was digested by microwave and the effect of acid medium on the digestion was studied.Under the optimal conditions,the detection limits of the six elements are in the range of 0.0005~0.01 μg/mL with the RSD≤2.6%.The recoveries are in the range of 95.7%~103.5%.The experimental results showed that the developed method is easy,rapid and accuracy.

Key concepts: Chemistry, Microwave digestion, Sargassum, Inductively coupled plasma atomic emission spectroscopy, Digestion (alchemy), Chromatography, Detection limit, Botany

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Elements in Sargassum fusiforme by Microwave Digestion ICP-AES — Research Paper | ScholarLens