2007Yaowu fenxi zazhiRequires access

Determination of Honokiol and Magnolol by semi-micro HPLC with electrochemical detection

Dongri Jin

Open publisher page 0 citations

Abstract

Objective:A highly sensitive and selective method was developed for the determination of honokiol and magnolol HPLC-ECD using a microbore column.Method:HPLC conditions were column CAPCELL PAK C18 UG120 S-3μm (1.0 mm×150 ram),methanol-water(64:36 and 60:40,v/v) containing 0.5 % phosphoric acid and polarization potential set at + 0.8 V(vs.Ag/AgCl).Result:Peak heights for honokiol and magnolol were found to be linearly related to the amount of each honokiol and magnolol injected from 2.5 fmol-7.5 pmol.Both of the detection limit(signal-noise ratio,S/N=3)of magnolol and honokiol were 0.5 fmol.The relative standard devia- tions(RSD,n=10)were less than 2.3 % at 50 fmol,1 pmol and 5 pmol for honokiol and magnolol.Conclusion: The proposed method was applied to determine honokiol and magnolol in traditional Chinese herbal medicines and human plasma sample.

About this research paper

What this paper is about

Objective:A highly sensitive and selective method was developed for the determination of honokiol and magnolol HPLC-ECD using a microbore column.Method:HPLC conditions were column CAPCELL PAK C18 UG120 S-3μm (1.0 mm×150 ram),methanol-water(64:36 and 60:40,v/v) containing 0.5 % phosphoric acid and polarization potential set at + 0.8 V(vs.Ag/AgCl).Result:Peak heights for honokiol and magnolol were found to be linearly related to the amount of each honokiol and magnolol injected from 2.5 fmol-7.5 pmol.Both of the detection limit(signal-noise ratio,S/N=3)of magnolol and honokiol were 0.5 fmol.The relative standard devia- tions(RSD,n=10)were less than 2.3 % at 50 fmol,1 pmol and 5 pmol for honokiol and magnolol.Conclusion: The proposed method was applied to determine honokiol and magnolol in traditional Chinese herbal medicines and human plasma sample.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:A highly sensitive and selective method was developed for the determination of honokiol and magnolol HPLC-ECD using a microbore column.Method:HPLC conditions were column CAPCELL PAK C18 UG120 S-3μm (1.0 mm×150 ram),methanol-water(64:36 and 60:40,v/v) containing 0.5 % phosphoric acid and polarization potential set at + 0.8 V(vs.Ag/AgCl).Result:Peak heights for honokiol and magnolol were found to be linearly related to the amount of each honokiol and magnolol injected from 2.5 fmol-7.5 pmol.Both of the detection limit(signal-noise ratio,S/N=3)of magnolol and honokiol were 0.5 fmol.The relative standard devia- tions(RSD,n=10)were less than 2.3 % at 50 fmol,1 pmol and 5 pmol for honokiol and magnolol.Conclusion: The proposed method was applied to determine honokiol and magnolol in traditional Chinese herbal medicines and human plasma sample.

Key concepts: Honokiol, Magnolol, Chemistry, Chromatography, Detection limit, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Honokiol and Magnolol by semi-micro HPLC with electrochemical detection — Research Paper | ScholarLens