2010•Journal of Guangxi Academy of SciencesRequires access

Determination of Chlorate and Perchlorate in Explosive Residues by Ion Chromatography

Lu Li

Open publisher page 0 citations

Abstract

The method was developed for the determination of chlorate and perchlorate in explosive residues by ion chromatography.The sample was separated by high capacity anion-exchange column(IonPac AS20) with gradient elution of KOH and determined by Ion Chromatography with suppressor conductivity detector.The result showed that chlorate and perchlorate is linear with excellent recurrence in the range from 1 mg/L to 100 mg/L.The detection limit,recovery and RSD of chlorate was 0.05mg/L,in the range of 96.4%~101.1%,and in the range of 3.2%~3.8% respectively.The detection limit,recovery and RSD of perchlorate was 0.1mg/L,in the range of 90.2%~102.3%,and in the range of 2.2%~4.4%.This method was rapid,accurate and sensitive,which can be applied to the real cases successfully.

About this research paper

What this paper is about

The method was developed for the determination of chlorate and perchlorate in explosive residues by ion chromatography.The sample was separated by high capacity anion-exchange column(IonPac AS20) with gradient elution of KOH and determined by Ion Chromatography with suppressor conductivity detector.The result showed that chlorate and perchlorate is linear with excellent recurrence in the range from 1 mg/L to 100 mg/L.The detection limit,recovery and RSD of chlorate was 0.05mg/L,in the range of 96.4%~101.1%,and in the range of 3.2%~3.8% respectively.The detection limit,recovery and RSD of perchlorate was 0.1mg/L,in the range of 90.2%~102.3%,and in the range of 2.2%~4.4%.This method was rapid,accurate and sensitive,which can be applied to the real cases successfully.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method was developed for the determination of chlorate and perchlorate in explosive residues by ion chromatography.The sample was separated by high capacity anion-exchange column(IonPac AS20) with gradient elution of KOH and determined by Ion Chromatography with suppressor conductivity detector.The result showed that chlorate and perchlorate is linear with excellent recurrence in the range from 1 mg/L to 100 mg/L.The detection limit,recovery and RSD of chlorate was 0.05mg/L,in the range of 96.4%~101.1%,and in the range of 3.2%~3.8% respectively.The detection limit,recovery and RSD of perchlorate was 0.1mg/L,in the range of 90.2%~102.3%,and in the range of 2.2%~4.4%.This method was rapid,accurate and sensitive,which can be applied to the real cases successfully.

Key concepts: Chlorate, Perchlorate, Ion chromatography, Detection limit, Chemistry, Chromatography, Thermal conductivity detector, Ion exchange

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorate and Perchlorate in Explosive Residues by Ion Chromatography — Research Paper | ScholarLens