2008•Xingshi jishuRequires access

Determination of residuary chlorate in explosion dust by Ion Chromatography

Zhou Ge-rong

Open publisher page 0 citations

Abstract

An ion chromatography method with suppression-conductivity detection has been developed for the detection of residuary chlorate in the soil after explosion with a high concentration of nitrate.Chlorate can be detected in 8 minutes with one step gradient elution of KOH and a high capacity anion-exchange column.The detection limit is 2.67 ng/ml(S/N=3).The method has broad linearity range(0.01~1000μg/ml),good linear correlation(r=0.9998)and low RSD(0.98%).When applied in two cases,the average recovery rates were above 99%.The influence of nitrate was also studied,and nitrate at 3000μg/ml does not in- terfere the determination of low chlorate.

About this research paper

What this paper is about

An ion chromatography method with suppression-conductivity detection has been developed for the detection of residuary chlorate in the soil after explosion with a high concentration of nitrate.Chlorate can be detected in 8 minutes with one step gradient elution of KOH and a high capacity anion-exchange column.The detection limit is 2.67 ng/ml(S/N=3).The method has broad linearity range(0.01~1000μg/ml),good linear correlation(r=0.9998)and low RSD(0.98%).When applied in two cases,the average recovery rates were above 99%.The influence of nitrate was also studied,and nitrate at 3000μg/ml does not in- terfere the determination of low chlorate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ion chromatography method with suppression-conductivity detection has been developed for the detection of residuary chlorate in the soil after explosion with a high concentration of nitrate.Chlorate can be detected in 8 minutes with one step gradient elution of KOH and a high capacity anion-exchange column.The detection limit is 2.67 ng/ml(S/N=3).The method has broad linearity range(0.01~1000μg/ml),good linear correlation(r=0.9998)and low RSD(0.98%).When applied in two cases,the average recovery rates were above 99%.The influence of nitrate was also studied,and nitrate at 3000μg/ml does not in- terfere the determination of low chlorate.

Key concepts: Chlorate, Chemistry, Ion chromatography, Detection limit, Chromatography, Nitrate, Gradient elution, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of residuary chlorate in explosion dust by Ion Chromatography — Research Paper | ScholarLens