Determination of Creatinine in Human Serum by Micellar Electrokinetic Capillary Chromatography

Zhou Xiao

Open publisher page 0 citations

Abstract

Objective To develop a new method for determining the concentration of serum creatinine using micellar electrokinetic capillary chromatography (MECC). Metkods The MECC was used with pH7. 2, 120 mmol/LSDS, 30 mmol/L phosphate buffer, with 21 cm ×50 μm ID. fused-silica uncoated capillary. The sample wasan UV-detector at 235 nm with creatinine as external standard. The running voltage wa 10kV. Results Thismethod was linear in range of 27. 65~7080 μmol/L with the detection limit of 9. 19 μmol/L. The recovery ratewas between 99. 8% to 105. 5 K. The within-run CV and between-run CV were less than 3. 0% and 3. 6%,respectively. Endogenous compounds and 10 commonly used drugs show no interference with this chromatographicprocedure. Conclusions The MECCmethod is a new, simple, rapid method for determination of serum creatinine.

About this research paper

What this paper is about

Objective To develop a new method for determining the concentration of serum creatinine using micellar electrokinetic capillary chromatography (MECC). Metkods The MECC was used with pH7. 2, 120 mmol/LSDS, 30 mmol/L phosphate buffer, with 21 cm ×50 μm ID. fused-silica uncoated capillary. The sample wasan UV-detector at 235 nm with creatinine as external standard. The running voltage wa 10kV. Results Thismethod was linear in range of 27. 65~7080 μmol/L with the detection limit of 9. 19 μmol/L. The recovery ratewas between 99. 8% to 105. 5 K. The within-run CV and between-run CV were less than 3. 0% and 3. 6%,respectively. Endogenous compounds and 10 commonly used drugs show no interference with this chromatographicprocedure. Conclusions The MECCmethod is a new, simple, rapid method for determination of serum creatinine.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a new method for determining the concentration of serum creatinine using micellar electrokinetic capillary chromatography (MECC). Metkods The MECC was used with pH7. 2, 120 mmol/LSDS, 30 mmol/L phosphate buffer, with 21 cm ×50 μm ID. fused-silica uncoated capillary. The sample wasan UV-detector at 235 nm with creatinine as external standard. The running voltage wa 10kV. Results Thismethod was linear in range of 27. 65~7080 μmol/L with the detection limit of 9. 19 μmol/L. The recovery ratewas between 99. 8% to 105. 5 K. The within-run CV and between-run CV were less than 3. 0% and 3. 6%,respectively. Endogenous compounds and 10 commonly used drugs show no interference with this chromatographicprocedure. Conclusions The MECCmethod is a new, simple, rapid method for determination of serum creatinine.

Key concepts: Micellar electrokinetic chromatography, Chromatography, Creatinine, Detection limit, Chemistry, Phosphate buffered saline, Linear range, Capillary action

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Creatinine in Human Serum by Micellar Electrokinetic Capillary Chromatography — Research Paper | ScholarLens