2004ElectrophoresisRequires access

Determination of creatinine in human serum by short‐end injection capillary zone electrophoresis

Angelo Zinellu, Ciriaco Carru, Maria Franca Usai, Salvatore Sotgia, Luca Deiana

Open publisher page 20 citations

Abstract

A new ultra-rapid free-solution capillary zone electrophoresis method to measure serum creatinine is presented. Procedural parameters such as injection mode, concentration and pH of phosphate running buffer and acidic deproteinization of serum samples were investigated. Short-end injection permits a decrease of the analysis time by injecting samples at the outlet end of a silica capillary closest to the detection window, so reducing the migration distance. Thus, when a capillary with an effective length of 10.2 cm and a 40 mmol/L sodium phosphate buffer pH 2.35 was used, the obtained migration time of the creatinine peak was the shortest never described before, about 1.1 min. These conditions give a good reproducibility of the migration times (coefficient of variation, CV% < 0.5) and the peak areas (CV% < 2.8). Intra- and interassay CV were 3.06 and 6.26%, respectively, and analytical recovery was 99.4%. We compared our proposed method to Jaffé colorimetric assay, by measuring serum creatinine in 128 normal subjects. The obtained data were analyzed by the Passing and Bablok regression and Bland-Altman test. Creatinine concentration in healthy subjects was also used to investigate on its relationships with plasma thiols levels.

About this research paper

What this paper is about

A new ultra-rapid free-solution capillary zone electrophoresis method to measure serum creatinine is presented. Procedural parameters such as injection mode, concentration and pH of phosphate running buffer and acidic deproteinization of serum samples were investigated. Short-end injection permits a decrease of the analysis time by injecting samples at the outlet end of a silica capillary closest to the detection window, so reducing the migration distance. Thus, when a capillary with an effective length of 10.2 cm and a 40 mmol/L sodium phosphate buffer pH 2.35 was used, the obtained migration time of the creatinine peak was the shortest never described before, about 1.1 min. These conditions give a good reproducibility of the migration times (coefficient of variation, CV% < 0.5) and the peak areas (CV% < 2.8). Intra- and interassay CV were 3.06 and 6.26%, respectively, and analytical recovery was 99.4%. We compared our proposed method to Jaffé colorimetric assay, by measuring serum creatinine in 128 normal subjects. The obtained data were analyzed by the Passing and Bablok regression and Bland-Altman test. Creatinine concentration in healthy subjects was also used to investigate on its relationships with plasma thiols levels.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new ultra-rapid free-solution capillary zone electrophoresis method to measure serum creatinine is presented. Procedural parameters such as injection mode, concentration and pH of phosphate running buffer and acidic deproteinization of serum samples were investigated. Short-end injection permits a decrease of the analysis time by injecting samples at the outlet end of a silica capillary closest to the detection window, so reducing the migration distance. Thus, when a capillary with an effective length of 10.2 cm and a 40 mmol/L sodium phosphate buffer pH 2.35 was used, the obtained migration time of the creatinine peak was the shortest never described before, about 1.1 min. These conditions give a good reproducibility of the migration times (coefficient of variation, CV% < 0.5) and the peak areas (CV% < 2.8). Intra- and interassay CV were 3.06 and 6.26%, respectively, and analytical recovery was 99.4%. We compared our proposed method to Jaffé colorimetric assay, by measuring serum creatinine in 128 normal subjects. The obtained data were analyzed by the Passing and Bablok regression and Bland-Altman test. Creatinine concentration in healthy subjects was also used to investigate on its relationships with plasma thiols levels.

Key concepts: Capillary electrophoresis, Creatinine, Chromatography, Chemistry, Reproducibility, Capillary action, Phosphate buffered saline, Coefficient of variation

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of creatinine in human serum by short‐end injection capillary zone electrophoresis — Research Paper | ScholarLens