2007•Chemical Research and ApplicationRequires access

Determination of pestcide malathion residue in garden spgarden stuff by SPE-HPLC

Xiaoxia Li

Open publisher page 0 citations

Abstract

A SPE-HPLC method has been developed for the determination of pesticide malathion residue in garden spgarden stuff.The research method showed that the liner relationship between peak area and sample size was satisfactory in the range of 0.5 μg·mL-1~50.0μg·mL-1,the coefficient of correlation(r2) was 0.9992;the limit of detection(LOD)was 0.05 μg·kg-1 and the limit of quantification(LOQ) was 0.5μg·mL-1;the recoveries were 86.3%~98.0% at the spiked levels of 0.5,30.0 and 50.0 μg·mL-1with the relative standard deviation(RSD) of 9.1%~0.6%.

About this research paper

What this paper is about

A SPE-HPLC method has been developed for the determination of pesticide malathion residue in garden spgarden stuff.The research method showed that the liner relationship between peak area and sample size was satisfactory in the range of 0.5 μg·mL-1~50.0μg·mL-1,the coefficient of correlation(r2) was 0.9992;the limit of detection(LOD)was 0.05 μg·kg-1 and the limit of quantification(LOQ) was 0.5μg·mL-1;the recoveries were 86.3%~98.0% at the spiked levels of 0.5,30.0 and 50.0 μg·mL-1with the relative standard deviation(RSD) of 9.1%~0.6%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A SPE-HPLC method has been developed for the determination of pesticide malathion residue in garden spgarden stuff.The research method showed that the liner relationship between peak area and sample size was satisfactory in the range of 0.5 μg·mL-1~50.0μg·mL-1,the coefficient of correlation(r2) was 0.9992;the limit of detection(LOD)was 0.05 μg·kg-1 and the limit of quantification(LOQ) was 0.5μg·mL-1;the recoveries were 86.3%~98.0% at the spiked levels of 0.5,30.0 and 50.0 μg·mL-1with the relative standard deviation(RSD) of 9.1%~0.6%.

Key concepts: Chromatography, Detection limit, Malathion, Relative standard deviation, Residue (chemistry), Correlation coefficient, Chemistry, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of pestcide malathion residue in garden spgarden stuff by SPE-HPLC — Research Paper | ScholarLens