2010Journal of Zhengzhou UniversityRequires access

A Potentiometric Titration Method for the Determination of Sodium Chloride in the Compound Peroxymonosulphate Powder

Feiqun Xue

Open publisher page 0 citations

Abstract

To develop a method for the determination of sodium chloride in the compound peroxymonosulphate powder,the test took sodium chloride basic reagent as comparison,and a potentiometric-argentometric titration method was established to measure the contents of sodium chloride at normal temperature.The results showed that the linear range of the sodium chloride was 10.0 mg~55.0 mg with the correlation coefficient of 0.999 7,the repeatability was good with RSD=1.11%,the average recovery with blank samples was 99.6% with RSD=0.88% and the average recovery was 99.1% with RSD=1.39%,which ensures its adequate accuracy.The method is simple and accurate.It could be adopted for the quality control of the contents of sodium chloride in the compound peroxymonosulphate powder.

About this research paper

What this paper is about

To develop a method for the determination of sodium chloride in the compound peroxymonosulphate powder,the test took sodium chloride basic reagent as comparison,and a potentiometric-argentometric titration method was established to measure the contents of sodium chloride at normal temperature.The results showed that the linear range of the sodium chloride was 10.0 mg~55.0 mg with the correlation coefficient of 0.999 7,the repeatability was good with RSD=1.11%,the average recovery with blank samples was 99.6% with RSD=0.88% and the average recovery was 99.1% with RSD=1.39%,which ensures its adequate accuracy.The method is simple and accurate.It could be adopted for the quality control of the contents of sodium chloride in the compound peroxymonosulphate powder.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To develop a method for the determination of sodium chloride in the compound peroxymonosulphate powder,the test took sodium chloride basic reagent as comparison,and a potentiometric-argentometric titration method was established to measure the contents of sodium chloride at normal temperature.The results showed that the linear range of the sodium chloride was 10.0 mg~55.0 mg with the correlation coefficient of 0.999 7,the repeatability was good with RSD=1.11%,the average recovery with blank samples was 99.6% with RSD=0.88% and the average recovery was 99.1% with RSD=1.39%,which ensures its adequate accuracy.The method is simple and accurate.It could be adopted for the quality control of the contents of sodium chloride in the compound peroxymonosulphate powder.

Key concepts: Potentiometric titration, Repeatability, Sodium, Reagent, Chemistry, Titration, Chloride, Electroanalytical method

Related papers

Back to paper searchBrowse research topicsOriginal source
A Potentiometric Titration Method for the Determination of Sodium Chloride in the Compound Peroxymonosulphate Powder — Research Paper | ScholarLens