2011Ningxia Medical JournalRequires access

Determination of sodium chloride in puerarin and sodium chloride injection by potentiometric titration

Pei Chen

Open publisher page 0 citations

Abstract

Objective To establish a method for determination of sodium chloride in puerarin and sodium chloride injection by potentiometric titration.Methods There was a silver electrode was used as indicator electrode,a double salt bridge SCE was used as reference electrode,and 0.1 mol/L silver nitrate was used as titrate.The contents of sodium chloride in puerarin and sodium chloride injection were determined by potentiometric titration.Results The calibration curve was linearity in the range of 4.50-108.06 mg and with correlation coefficient of 1.000,the average recovery was 99.0%,the relative standard deviation(RSD) was 0.3%.Conclusion This method is quick,accurate and noninterference,and it can be adopted for quality control of puerarin and sodium chloride injection.

About this research paper

What this paper is about

Objective To establish a method for determination of sodium chloride in puerarin and sodium chloride injection by potentiometric titration.Methods There was a silver electrode was used as indicator electrode,a double salt bridge SCE was used as reference electrode,and 0.1 mol/L silver nitrate was used as titrate.The contents of sodium chloride in puerarin and sodium chloride injection were determined by potentiometric titration.Results The calibration curve was linearity in the range of 4.50-108.06 mg and with correlation coefficient of 1.000,the average recovery was 99.0%,the relative standard deviation(RSD) was 0.3%.Conclusion This method is quick,accurate and noninterference,and it can be adopted for quality control of puerarin and sodium chloride injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determination of sodium chloride in puerarin and sodium chloride injection by potentiometric titration.Methods There was a silver electrode was used as indicator electrode,a double salt bridge SCE was used as reference electrode,and 0.1 mol/L silver nitrate was used as titrate.The contents of sodium chloride in puerarin and sodium chloride injection were determined by potentiometric titration.Results The calibration curve was linearity in the range of 4.50-108.06 mg and with correlation coefficient of 1.000,the average recovery was 99.0%,the relative standard deviation(RSD) was 0.3%.Conclusion This method is quick,accurate and noninterference,and it can be adopted for quality control of puerarin and sodium chloride injection.

Key concepts: Potentiometric titration, Puerarin, Sodium, Titration, Chloride, Calibration curve, Sodium nitrate, Silver nitrate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of sodium chloride in puerarin and sodium chloride injection by potentiometric titration — Research Paper | ScholarLens