HPLC-DAD-ELSD simultaneous determination of spinosin,jujuboside A and jujuboside B in Semen Ziziphi Spinosae(Suanzaoren)
Pei Miao-rong
Abstract
Pei Miao-rong
Abstract
Objective:To establish an HPLC-DAD-ELSD method for the simultaneous determination of spinosin,jujuboside A and jujuboside B in Semen Ziziphi Spinosae.Methods:The assay was performed on a Grace Brava C18-BDS(250 mm×4.6 mm,5 μm) column by a gradient elution program with acetonitrile-water as mobile phase at a flow rate of 1.0 mL·min-1.The detection wavelength of DAD was 335 nm and the evaporator tube temperature of ELSD was set at 100 ℃ with the nebulizing gas flow-rate of 2.9 L·min-1.The temperature of column was kept at 25 ℃.Results:The linear ranges of spinosin,jujuboside A and jujuboside B were 59.40-594.0 μg·mL-1(r=0.9996),49.50-900.0 μg·mL-1(r=0.9998),20.40-407.2 μg·mL-1(r=0.9999),respectively.The average recoveries(n=6) were 96.9%(RSD=1.8%),101.2%(RSD=2.5%),100.3%(RSD=2.9%),respectively.Conclusion:The method is accurate and reliable for simultaneous determination of multiple index components under the same chromatographic condition,and provides a reference for comprehensive quality evaluation of Semen Ziziphi Spinosae.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish an HPLC-DAD-ELSD method for the simultaneous determination of spinosin,jujuboside A and jujuboside B in Semen Ziziphi Spinosae.Methods:The assay was performed on a Grace Brava C18-BDS(250 mm×4.6 mm,5 μm) column by a gradient elution program with acetonitrile-water as mobile phase at a flow rate of 1.0 mL·min-1.The detection wavelength of DAD was 335 nm and the evaporator tube temperature of ELSD was set at 100 ℃ with the nebulizing gas flow-rate of 2.9 L·min-1.The temperature of column was kept at 25 ℃.Results:The linear ranges of spinosin,jujuboside A and jujuboside B were 59.40-594.0 μg·mL-1(r=0.9996),49.50-900.0 μg·mL-1(r=0.9998),20.40-407.2 μg·mL-1(r=0.9999),respectively.The average recoveries(n=6) were 96.9%(RSD=1.8%),101.2%(RSD=2.5%),100.3%(RSD=2.9%),respectively.Conclusion:The method is accurate and reliable for simultaneous determination of multiple index components under the same chromatographic condition,and provides a reference for comprehensive quality evaluation of Semen Ziziphi Spinosae.
Key concepts: Chemistry, Chromatography, Gradient elution, Semen, High-performance liquid chromatography, Chromatography detector, Elution, Biology