2007Unpublished venueRequires access

Determination of Pb in Cigarette Tipping Paper by Flow Injection-Hydride Generation-atomic Absorption Spectrometry

Guoku Chao

Open publisher page 0 citations

Abstract

The method of measuring trace Pb in tipping paper by flow injection-Hydride generation-atomic absorption spectrometry was studied. The optimum experiment conditions for hydride generation were investigated.Recovery of the method was 95.0% ~104.5%,and detection limit was 0.22 ng/mL,linearity was kept in range of 0~50 ng/mL,the linear regression equation is y= 0.012x+0.0106,the correlation coefficient is 0.999 7,and the relative standard deviation(RSD) was 1.2% ~ 3.3 %.

About this research paper

What this paper is about

The method of measuring trace Pb in tipping paper by flow injection-Hydride generation-atomic absorption spectrometry was studied. The optimum experiment conditions for hydride generation were investigated.Recovery of the method was 95.0% ~104.5%,and detection limit was 0.22 ng/mL,linearity was kept in range of 0~50 ng/mL,the linear regression equation is y= 0.012x+0.0106,the correlation coefficient is 0.999 7,and the relative standard deviation(RSD) was 1.2% ~ 3.3 %.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method of measuring trace Pb in tipping paper by flow injection-Hydride generation-atomic absorption spectrometry was studied. The optimum experiment conditions for hydride generation were investigated.Recovery of the method was 95.0% ~104.5%,and detection limit was 0.22 ng/mL,linearity was kept in range of 0~50 ng/mL,the linear regression equation is y= 0.012x+0.0106,the correlation coefficient is 0.999 7,and the relative standard deviation(RSD) was 1.2% ~ 3.3 %.

Key concepts: Hydride, Atomic absorption spectroscopy, Detection limit, Chemistry, Analytical Chemistry (journal), Relative standard deviation, Linearity, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Pb in Cigarette Tipping Paper by Flow Injection-Hydride Generation-atomic Absorption Spectrometry — Research Paper | ScholarLens